Installation Sheet

7301948-100
- 2 -
BACK-TO-BACK INSTALLATION
Recommended fitting type for
back-to-back installations.
Depending upon your plumbing and venting conditions, the flow from the Cadet
®
PRO in a
back-to-back installation may create a vacuum on the system and draw water from the opposing
bowl. The National Standards Plumbing Code prohibits the use of a cross fitting for drainage as
throw over is possible. The code does approve a directional "Y" style fitting with proper venting to
direct the water downward and away from the other toilet.
Press firmly.
NOTE: 1/4" EZ-BOLTS INCLUDED.
IF 5/16" BOLTS ARE REQUIRED,
PURCHASE SEPARATELY.
Wax Ring
(sold separately)
1 2
Turn Off Water Supply
Flush to remove
water from tank;
sponge remaining
water from
bowl before
removing toilet.
Clean Flange
Before You Start:
If Removing An Existing Toilet
!
Caution: If leaving floor flange
open for more than 1-2 hours,
cover flange to prevent escaping
sewer gases.
ROUGHING-IN DIMENSIONS:
NOTE:
Distance from wall to closet flange centerline must be as shown below.
492mm
(19-3/8")
356mm
(14")
815mm
(32-1/16")
82mm
(3-1/4")
FINISHED
WALL
FINISHED
FLOOR
305mm
(12")
294mm
(11-9/16")
31mm
(1-1/4")
305mm
(12")
419mm
(16-1/2")
470mm
(18-1/2")
894mm
(35-3/16")
140mm
(5-1/2")
FINISHED
WALL
492mm
(19-3/8")
356mm
(14")
815mm
(32-1/16")
82mm
(3-1/4")
FINISHED
WALL
FINISHED
FLOOR
305mm
(12")
294mm
(11-9/16")
31mm
(1-1/4")
305mm
(12")
419mm
(16-1/2")
419mm
(16-1/2")
140mm
(5-1/2")
843mm
(33-3/16")
FINISHED
WALL
Elongated Model 216AD Series Round Front Model 216BD Series