Installation manual
35
I. PREPARATION FOR OPERATION/START-UP
The following items should be checked before attempting to operate the dryer:
1. Read
ALL “CAUTION,” “WARNING,” and “DIRECTION” labels attached to the dryer.
2. Check incoming supply voltage to be sure that it is the same as indicated on the dryer data label affixed to
either the back side of the upper control door or left side panel/wall area behind the control door. In the
case of 208 VAC or 230/240 VAC, THE SUPPLY VOLTAGE MUST MATCH THE ELECTRIC
SERVICE EXACTLY.
3. GAS MODELS - check to assure that the dryer is connected to the type of heat/gas indicated on the
dryer data label.
4. GAS AND ELECTRIC MODELS - the sail switch damper assembly was installed and adjusted at the
factory prior to shipping. However, each sail switch adjustment must be checked to assure that this
important safety control is functioning.
5. Check bolts, nuts, screws, terminals, and fittings for tightness and security.
6. GAS MODELS - be sure that ALL gas shutoff valves are in the open position.
7. Check ALL back guard panels and service box covers have been replaced.
8. Check the lint drawer to assure that it is closed and secured in place.
9. Rotate the basket (tumbler/drum) by hand to be sure it moves freely.
10. STEAM MODELS - check to insure that a clean, dry, regulated air supply 80 PSI (5.52 bars) is connected
to the dryer (air operated damper system only).
11. STEAM MODELS - check to insure ALL steam shutoff valves are open.
12. STEAM MODELS - check steam damper operation.
13. Check basket (tumbler) bearing setscrews to insure that they are ALL tight.
14. Check vent is connected to the machine and is exhausted to the outdoors.
15. There should be a source of fresh air entering the room. This source should not be near where the
dryer(s) exhaust to the outside.