Wiring Sheet

FOR SERVICE TECHNICIAN’S USE ONLY
© 2019
W11326823A
ACTIVATING THE SERVICE DIAGNOSTIC MODES
1. Enter Diagnostics Mode by pressing CANCEL>CANCEL>START within 5
seconds.
2. Press the “up” arrow keypad to scroll through the diagnostics settings.
NOTES:
Entering Diagnostics mode will cancel any active oven operation.
Enter the Diagnostics mode only after the oven is cool.
Code Description
No display Control not operational
F1E0
F1E1
F1E2
Internal board failure
A/D Error(s)
F2E1 Shorted keypad
F3E0 Oven sensor opened
Oven sensor shorted
Bake/Broil range over temperature
Clean range over temperature
F5E0 Door and switches do not agree (Clean mode)
F5E1 Door latch not operating (Clean mode)
F6E1 Oven over temperature when heating
F9E0 Miswired house
Miswired range
ERROR CODES
RESISTANCES
Component Pinout Resistance or Voltage
Door switch P3-1 to P3-2 2 VDC with door open
0 VDC with door closed
Oven temp sensor P3-4 to P3-5 1000-1200 Ω at room temperature.
Oven light P2-1 to WH (neutral) P1-3 0-40 Ω nominal
Bake element P4-3 to P5-4 10-40 Ω nominal
Broil element P5-1 to P5-4 10-40 Ω nominal
Thermo fuse P5-1 to P5-4 240 VAC
Door latch motor P3-3 to WH (neutral) P1-3 500-3000 Ω
Radiant element (single) H1 to H2 240 VAC
Radiant element (dual) H1A to H2 240 VAC
Coil element H1 to H2 240 VAC
DANGER
Electrical Shock Hazard
Only authorized technicians should
perform diagnostic voltage measurements.
After performing voltage measurements,
disconnect power before servicing.
Failure to follow these instructions can
result in death or electrical shock.
Voltage Measurement Safety Information
When performing live voltage measurements, you must do the following:
Verify the controls are in the off position so that the appliance does not start when energized.
Allow enough space to perform the voltage measurements without obstructions.
Keep other people a safe distance away from the appliance to prevent potential injury.
Always use the proper testing equipment.
After voltage measurements, always disconnect power before servicing.
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.

Summary of content (2 pages)