User Manual
Table Of Contents
- BreezeMAX® Extreme
- System Manual
- About This Manual
- Contents
- System Description
- 1.1 About WiMAX
- 1.2 WiMAX Network Architecture
- 1.3 BreezeMAX Extreme
- 1.4 Specifications
- 1.4.1 General Modem & Radio
- 1.4.2 3.x GHz BTS
- 1.4.3 5 GHz BTS
- 1.4.4 Sensitivity
- 1.4.5 3.x GHz Antennas
- 1.4.6 5 GHz Antennas
- 1.4.7 Power Supply
- 1.4.8 GPS Antennas
- 1.4.9 Data Communication (Ethernet Port)
- 1.4.10 Configuration and Management
- 1.4.11 Environmental
- 1.4.12 BTS Standards Compliance, General
- 1.4.13 Notes on Maximum Tx Power Limitations for 5 GHz Units:
- Installation
- 2.1 BTS Installation
- 2.2 GPS Installation
- 2.3 Indoor Power Supply Installation
- 2.4 Cable Connections
- 2.5 External Antennas Connection
- Commissioning
- Operation and Administration
- 4.1 BreezeMAX Extreme System Management
- 4.2 The Monitor Program
- 4.3 IP Addresses Configuration
- 4.4 The Main Menu
- 4.5 BTS Menu
- 4.5.1 Show Summary
- 4.5.2 Show Properties
- 4.5.3 Configuration
- 4.5.4 Unit Control
- 4.5.5 Fault Management
- 4.5.6 Performance Counters
- 4.6 ASN-GW Menu
- 4.6.1 AAA
- 4.6.2 Services Menu
- 4.6.2.1 Common Operations in Services Menus
- 4.6.2.2 MSs Services
- 4.6.2.3 Service Profiles
- 4.6.2.4 QoS Profiles
- 4.6.2.5 Multiple Service Flows
- 4.6.2.6 Service Rules
- 4.6.2.7 Classifiers
- 4.6.2.8 Service Groups
- 4.6.2.9 Service Interfaces
- 4.6.2.9.1 Service Interface ID
- 4.6.2.9.2 Service Interface Name
- 4.6.2.9.3 Forwarding Rule Name
- 4.6.2.9.4 CS Type
- 4.6.2.9.5 VLAN Interface
- 4.6.2.9.6 VLAN Transparency
- 4.6.2.9.7 VLAN ID
- 4.6.2.9.8 VLAN Priority Marking
- 4.6.2.9.9 VLAN Priority
- 4.6.2.9.10 VLAN List
- 4.6.2.9.11 Inner DSCP Marking
- 4.6.2.9.12 Inner DSCP
- 4.6.2.10 Forwarding Rules
- 4.7 Sector Menu
- 4.8 BS Menu
- 4.9 Radio Channel Menu
- 4.10 Antenna Menu
- 4.11 GPS Menu
- 4.12 MS Menu
- 4.13 Parameters Summary
- Glossary
Chapter 4 - Operation and Administration GPS Menu
BreezeMAX Extreme 166 System Manual
4.11.2.1.6 Daylight Saving
The Daylight Saving parameter is used to enable or disable the daylight saving
feature using the following Start Date, End Date and Advance Hour Factor
parameters.
The default is Disable
4.11.2.1.7 Start Date
When Daylight Saving is enabled, this parameter defines the date for starting the
daylight saving feature. At the beginning of this date (midnight at the beginning of
this date), the clock will be advanced by the amount of hours specified by the
Daylight Saving Advance Factor (see below).
Use the format dd:mm to define the date and month at which to start activating
the Daylight Saving feature.
4.11.2.1.8 End Date
When Daylight Saving is enabled, this parameter defines the date for ending the
daylight saving feature (at “Daylight Saving Advance Factor” hours after midnight
at the end of this date).
Use the format dd:mm to define the date and month at which to end activating the
Daylight Saving feature.
4.11.2.1.9 Advance Hour Factor
This parameter enables configuring the amount of time by which the clock should
be advanced during the daylight saving period.
The range is from 0 to 4:45 (hours) in steps of 15 minutes.
4.11.2.2 Clock Parameters
In the current release Clock Parameters are not configurable. The Show option for
Clock Parameters displays the default Clock Mode (Master) and the sources for
the main clocks in the system according to the Clock Mode.
The Clock Parameters submenu includes the following:
Clock Mode
External 1PPS Clock
External 10MHz Clock