User Manual
Table Of Contents
- BreezeMAX® Extreme
- System Manual
- About This Manual
- Contents
- System Description
- 1.1 About WiMAX
- 1.2 WiMAX Network Architecture
- 1.3 BreezeMAX Extreme
- 1.4 Specifications
- 1.4.1 General Modem & Radio
- 1.4.2 3.x GHz BTS
- 1.4.3 5 GHz BTS
- 1.4.4 Sensitivity
- 1.4.5 3.x GHz Antennas
- 1.4.6 5 GHz Antennas
- 1.4.7 Power Supply
- 1.4.8 GPS Antennas
- 1.4.9 Data Communication (Ethernet Port)
- 1.4.10 Configuration and Management
- 1.4.11 Environmental
- 1.4.12 BTS Standards Compliance, General
- 1.4.13 Notes on Maximum Tx Power Limitations for 5 GHz Units:
- Installation
- 2.1 BTS Installation
- 2.2 GPS Installation
- 2.3 Indoor Power Supply Installation
- 2.4 Cable Connections
- 2.5 External Antennas Connection
- Commissioning
- Operation and Administration
- 4.1 BreezeMAX Extreme System Management
- 4.2 The Monitor Program
- 4.3 IP Addresses Configuration
- 4.4 The Main Menu
- 4.5 BTS Menu
- 4.5.1 Show Summary
- 4.5.2 Show Properties
- 4.5.3 Configuration
- 4.5.4 Unit Control
- 4.5.5 Fault Management
- 4.5.6 Performance Counters
- 4.6 ASN-GW Menu
- 4.6.1 AAA
- 4.6.2 Services Menu
- 4.6.2.1 Common Operations in Services Menus
- 4.6.2.2 MSs Services
- 4.6.2.3 Service Profiles
- 4.6.2.4 QoS Profiles
- 4.6.2.5 Multiple Service Flows
- 4.6.2.6 Service Rules
- 4.6.2.7 Classifiers
- 4.6.2.8 Service Groups
- 4.6.2.9 Service Interfaces
- 4.6.2.9.1 Service Interface ID
- 4.6.2.9.2 Service Interface Name
- 4.6.2.9.3 Forwarding Rule Name
- 4.6.2.9.4 CS Type
- 4.6.2.9.5 VLAN Interface
- 4.6.2.9.6 VLAN Transparency
- 4.6.2.9.7 VLAN ID
- 4.6.2.9.8 VLAN Priority Marking
- 4.6.2.9.9 VLAN Priority
- 4.6.2.9.10 VLAN List
- 4.6.2.9.11 Inner DSCP Marking
- 4.6.2.9.12 Inner DSCP
- 4.6.2.10 Forwarding Rules
- 4.7 Sector Menu
- 4.8 BS Menu
- 4.9 Radio Channel Menu
- 4.10 Antenna Menu
- 4.11 GPS Menu
- 4.12 MS Menu
- 4.13 Parameters Summary
- Glossary
Chapter 4 - Operation and Administration BTS Menu
BreezeMAX Extreme 91 System Manual
4.5.5.2 Show Active Alarm Log Table
Select to view the currently active alarms. For each active alarm, the following
details are displayed:
Seq#: The sequential identification number of the event (trap).
Time: The Date and Time at which the alarm was generated.
MO Type & Instance: The Type and Instance (ID number) of the applicable
Managed Object. The possible MO Types are BTS, ASN GW, AAA, Sector, BS,
Radio Channel, GPS, Antenna, MS, and MS Service.
Event Type: The type of event (first level of event description).
Probable Cause: The probable cause of the event (second level of event
description).
Specific Problem: The specific problem that caused the event (third level of
event description).
Alarm Severity: The defined severity of the Alarm.
Object Severity: The combined events severity for the Managed Object at the
time the alarm was generated.
For more details on alarms, refer to the Traps and Alarms document.
4.5.5.3 Event Log Selection Criteria
This submenu enables Select to view/update the filtering criteria for the Show
Event Log Table By Selection Criteria display (see “Show Event Log Table By
Selection Criteria” on page 92). For more details on events refer to the Traps and
Alarms document. The configurable filtering criteria are:
Minimum Severity
Last Days
Managed Object Type
Specific Event Category