User's Manual

C l e a n i n g a n d M a i n t e n a n c e
128.
ALLOW THE UNIT TO PREHEAT FOR 30 MINUTES.
After a period of 30 minutes
PRESS THE ON/OFF POWER KEY TO THE OFF POSITION.
6. Open the oven door. USING HAND PROTECTION, rotate the Steam Generator Drain Cap until
water begins to flow from the four holes in the cap. In approximately 20 to 60 seconds, a sufficient
quantity of water will have drained from the steam generator so that the drain cap can be completely
removed. Let the water continue to drain until the flow completely subsides.
7. Loosen the thumb screw(s) and swing Fan Guard Cover Plate toward the back of the oven. Using
the hand-held hose, direct a stream of water directly into the Steam Generator Drain and Steam
Exit Port several times. Close the swing-out Cover Plate . Lock the cover into place and tighten
thumb screw(s). Close the oven door.
PRESS THE ON/OFF POWER KEY TO THE ON POSITION.
A new supply of fresh water will begin to flush the steam generator.
ALLOW THE WATER TO RUN FOR 2 MINUTES
to continue to flush out all remaining solution.
PRESS THE ON/OFF POWER KEY TO THE OFF POSITION.
8. Open oven door. USING HAND PROTECTION, replace the Steam Generator Drain Cap by
turning it clockwise until there is a slight resistance. Close oven door.
PRESS THE ON/OFF POWER KEY TO THE ON POSITION.
The unit will start to fill.
PRESS THE STEAM MODE KEY AND THEN PRESS THE START KEY.
ALLOW UNIT TO RUN FOR 20 MINUTES IN THE STEAM MODE.
PRESS THE ON/OFF POWER KEY TO THE OFF POSITION.
9. Open the oven door. USING HAND PROTECTION, rotate the Steam Generator Drain Cap until
water begins to flow from the four holes in the cap. In approximately 20 to 60 seconds, a sufficient
quantity of water will have drained from the steam generator so that the drain cap can be completely
removed. Let the water continue to drain until the flow completely subsides. Replace the Steam
Generator Drain Cap by turning it clockwise until there is a slight resistance.
At the end of the production day, leave the door slightly ajar.
THE UNIT IS NOW READY TO BE USED.
DO NOT COOK IN ANY PROGRAM MODE WITH
ScaleFree
OR VINEGAR IN THE STEAM GENERATOR SYSTEM.
C l e a n i n g a n d M a i n t e n a n c e E L E C T R I C M O D E L S
STANDARD CONTROL
DELUXE CONTROL