User's Manual

Category:
External
Product/Project:
INSTALLATION
Page:
10 (12)
Subject:
INSTALLATION MANUAL SESAM 6099 TRANSMITTER
Document ID:
939045-000
Date:
2008-01-18
Written by:
Henrik Ring
Checked by:
Anders Modig
Approved by:
Henrik Ring
Version:
A1
ÅKERSTRÖMS BJÖRBO AB, SE-780 45 BJÖRBO, Sweden
Phone +46 241 25 000, Fax +46 241 232 90
Vat No SE556153982501 Registrated office BJÖRBO
www.akerstroms.se
7. PIN lock (0-9999) Pin (default – 0000, pin lock disabled)
This option allows the transmitter operator panel to be locked for unauthorized use.
The PIN code is a four digit number (0-9999).
The lock can be activated manually or automatically after a given time of inactivity, see
configuration option 8 below.
Note! The PIN code must be set to a number greater than 0. Enter PIN code 0000 to disable the PIN
lock.
To set a new PIN code do the following:
While in the configuration menu press the ’7’ button twice. The display will show
oLd
Enter the old 4-digit PIN code. Enter 0000 if the code has never been set.
neu
Enter a new 4-digit PIN code. Enter 0000 to disable the PIN code.
rpt
Enter the new 4-digit PIN code again.
Press the store button B8 to save the new setting.
To manually activate the PIN lock, exit the configuration menu and press the B8 key for 3 seconds
until the display shows Pin .
Unlocking the transmitter: When the display shows Pin the transmitter is locked and a 4–digit
PIN code must be entered before use. If the correct code is entered the display will show PAS If
an incorrect code is entered the display will show err
Note! If an incorrect PIN is entered 3 times in a row the transmitter will be locked for 2 minutes.
During this time the display will show Loc
8. Automatic PIN lock delay (0-999 min) dLy (default – 0, off)
This option sets the duration from the last key press until automatic PIN lock. The PIN-code must
be set prior to this option, see configuration option 7. To set a new duration press button ’8’ again
when the display shows dLy
The delay is set in minutes (0-999). Enter 0 to disable the automatic PIN lock.
9. Transmit teach-in message (on/off) tin (default – off)
This option is used when pairing a transmitter with a receiver (teach-in). Toggle this option to on
to activate the id transmit mode. This option automatically switches to off after 2 seconds after it
has been enabled.
0. Display customer ID and serial number Cid
This option displays the transmitter customer ID and serial number. The customer ID is a part of the
transmitter identity. This value is factory programmed for each of Åkerströms OEM customers and
can not be changed. Only transmitters with the same customer id setting can be used together in a
system. The serial number is also factory programmed and unique for every Sesam 6099
transmitter. The serial number can be used in the 6000c receiver.