Installation Instructions
1. Remove tank lid at the inlet side of the access.
2. Place hose in tank be cautious not to damage internal
components.
3. Use mixer to break-up solids and help pumping process.
4. Pump system no more than half empty and be sure to
replenish tank volume with water to avoid oating tank.
5. Reinstall access lid.
SECTION 2: MAINTAINING A SEPTIC SYSTEM
2.2 INSPECT TANK SLUDGE LEVEL
1. Remove tank lid at the inlet side of the access.
2. Assemble sludge judge and insert into tank.
3. Take reading of sludge by pulling up on check valve and removing from tank.
4. Reinstall access lid.
NOTE: If oating scum is within 6 inches of the bottom of the outlet tee or sludge is
within 12 inches, then it is time to have the tank pumped.
2.3 PUMP SLUDGE FROM TANK
Pump if 6” or 12”