Note
CT AGC/PC values set via the Sitespan are not be stored in the NVRAM of the RF
unless it is power cycled. In normal commissioning operation, this does not cause any
problem because when the rack is power cycled, the RF cards are reset, the AGC/PC
values will be stored. However if a modem shelf is reset and not the rack, then the RF
cards are not reset and the commissioned values will be lost. After any power down of
a modem shelf:
A) hot plug the RF card, (trigger the saving of the commissioned values)
B) power cycle the shelf (clears the RF alarms)