Brochure
Physical Damage Protection
Weather Damage Protection
U.S. Patents #9,091,377 B2
#9,523,200 B2
TSS Series
TGS Series
Copyright © 2017 Airex Manufacturing, Inc.
Seals HVAC Piping Wall Penetrations
Energy Efficient Product
*Based on HVAC Industry and Manufacturer’s Independent Study on a
Combined ROI & Sustainable Energy Savings Calculation. A contributing
product to the U.S. Energy Department’s 30% Energy Savings Solution Initiative.
Seals Piping Wall Penetrations
TITAN OUTLET
TM
Siding or
Compact
Applications
Building Codes
Energy Codes
Residential Codes
Mechanical Codes
Green Codes
Meets New Code
Requirements:
72170 Dunham Way, Suite D | Thousand Palms, CA 92276 | (760) 343-2277 | FAX (760) 501-7912 | www.airexmfg.com
Residential Commercial Multi-Family Units
Approved Material & Performance Testing
Codes & Standards Compliance
MADE IN USA
• Superior Durable Quality with U/V Resistance & High
Impact Strength Design
• Gasket Compression System Seals Wall Air Leakage &
Weather Moisture Wall Damage
• Flexible Elastomeric Outlet Sleeve Design Prevents Air
Infiltration & Rodent Intrusion
• Design Supports HVAC Systems with Wall Isolation &
Anti-Vibration Features
• Flexible Sleeve Reduces Piping Vibration & Noise
• Seals to Protect Indoor Air Quality
• ASTM E283 – Standard Test Method for Air Leakage
• ASTM E331 – Standard Test Method for Water Penetration
• ASTM E 2178 - Air Permeance of Building Materials
Wall Mounted Outlet (Outdoor-Rated Rigid Plastic)
• ASTM D1525C-09 - Temperature Deformation Test
• ASTM D648-07 - Temperature Load Deformation Test
• UL 94 HB - Flammability Test
• UL 746C - Outdoor Suitability - f1 Rating
Wall Outlet Sleeve (Outdoor-Rated Elastomeric Plastic)
• ASTM D573-04 - Deterioration Test
• ASTM D746-07 - Brittleness Temperature Impact Test
30
%
30
%
Mandate
Energy
Savings
Mandate
Air Leakage and Wall Penetration Compliance per:
Air Leakage (Mandatory): Residential Section 402.4
The building thermal envelope shall be constructed to limit air leakage
in accordance with the requirements of Sections R402.4.1 through
R402.4.4.
2012, 2015, 2018 International Energy Conservation Code
(
IECC
)
Air Barrier Construction: Commercial Section C402.5.1.1
Penetrations of the air barrier shall be caulked, gasketed or sealed in
a manner compatible with the construction materials and locations...
M
o
l
d
G
r
o
w
t
h
S
n
o
w
I
c
e
F
o
r
m
a
t
i
o
n
B
l
a
z
i
n
g
S
u
n
U
V
R
a
d
i
a
t
i
o
n
D
a
m
a
g
e
P
i
p
e
V
i
b
r
a
t
i
o
n
I
n
d
o
o
r
A
i
r
Q
u
a
l
i
t
y
P
r
o
t
e
c
t
i
o
n
I
n
f
i
l
t
r
a
t
i
o
n
A
i
r
L
e
a
k
a
g
e
R
a
i
n
-
W
i
n
d
M
o
i
s
t
u
r
e
S
y
s
t
e
m
R
e
m
o
v
a
b
l
e
-
R
e
u
s
a
b
l
e
R
o
d
e
n
t
s
I
n
s
e
c
t
s
• IBC - 2006, 2009, 2012, 2015, 2018 Chapter 13
• IRC - 2006, 2009, 2012, 2015, 2018 Chapter 11 Part IV Energy Efficiency - Section N1101 General -
N1101.1 Scope - Air Leakage Section N1102.4 Section N1102.4.1 - Building Thermal Envelope - (1. All
joints, seams, penetrations) Chapter 11 Refrigeration Section 1101.0 Scope -1101.3 Protection
• IECC - 2012, 2015, 2018 Air Leakage (Mandatory) - Residential Section 402.4.1 and 402.4.1.1 Building
Thermal Envelope – Penetrations
• IECC -
2012, 2015, 2018 Air Leakage (Mandatory) - Commercial Section C402.4.3 and C402.4.2
Building Thermal Envelope – Penetrations
• IMC - 2006, 2009, 2012, 2018 Chapter 3 General Regulations Section 301.1 Scope – Sections 301.10,
301.11, 301.14, 301.15, 305.1, 305.2, 305.4
• UMC - 2006, 2009, 2012, 2018 Chapter 11 Refrigeration – Section 1101.0 Scope - Section 1101.1 -
General Requirements Section 1106.0 – Section 1106.2, Section 1111.0 Erection of Refrigerant Piping –
Sections 1111.1, 1111.2, 1111.4
• California Building Energy Efficiency Standards (Title 24 Energy Code) 2016,
2019 Part 6 Section 110.7-
Mandatory Requirements to Limit Air Leakage
Central
Systems
Mini-Split
Systems
Applications for: