INSTALLATION GUIDELINES
ALUMINUM MINI LOUVERS
These installation guidelines are for use with typical or standard applications. It is always recommended to seek advice from a licensed professional,
and to check with your local building inspector or building permit office for approvals and possible variations that may apply.
Mini Louvers are used to seal
existing rafter/bird block vent holes
to maximize airflow while protect-
ing against rodent and insect inva-
sion.
If there are no pre-existing birdblock
holes, use a hole saw drill bit to cut
holes to the nominal size of the Mini
Louver Vent: 2, 3 or 4 inch.
Lightly tap in the vents to pressure fit.
B
A
C
A: Stem diameter
B: Face diameter
C: Stem depth
Note: N.F.V. value is square inches.
ML2 1.88" 2.31" 0.5" 0.47"
ML3 2.88" 3.50" 0.63" 1.34"
ML4 3.88" 4.31" 0.63 2.88"
A B C N.F.V.