Problem Possible cause Solution
The temperature in
the appliance is too
low/high.
The temperature regula-
tor is not set correctly.
Set a higher/lower temper-
ature.
If your appliance is still not working
properly after making the above checks,
please contact the After Sales Centre.
6.1 Replacing the control unit
The appliance is equipped with a long-
life LED interior light.
Only service is allowed to replace the
control unit. Contact your Service Cen-
ter.
6.2 Closing the door
1.
Clean the door gaskets.
2.
If necessary, adjust the door. Refer
to "Installation".
3.
If necessary, replace the defective
door gaskets. Contact the Service
Center.
7. INSTALLATION
7.1 Positioning
WARNING!
If you are discarding an old appli-
ance that has a lock or catch on
the door, you must ensure that it
is made unusable to prevent
young children being trapped in-
side.
The appliance shall have the
plug accessible after installation.
Install this appliance at a location where
the ambient temperature corresponds to
the climate class indicated on the rating
plate of the appliance:
Cli-
mate
class
Ambient temperature
SN +10°C to + 32°C
N +16°C to + 32°C
ST +16°C to + 38°C
T +16°C to + 43°C
7.2 Electrical Connection
CAUTION!
Any electrical work required to
install this appliance should be
carried out by a qualified electri-
cian or competent person.
WARNING!
This appliance must be earthed.
The manufacturer declines any li-
ability should these safety meas-
ures not be observed.
AB
C
D
E
The wires in the mains lead are
coloured in accordance with the
following code:
A Green and Yellow: Earth
CBrown: Live
E Blue: Neutral
12