What to do if ...
818 34 57-00/4 91
If after the above checks there is still a fault, call your local AEG Service
Force Centre.
In-guarantee customers should ensure that the above checks have been
made as the engineer will make a charge if the fault is not a
mechanical or electrical breakdown.
Please note that proof of purchase is required for in-guarantee service
calls.
An alarm sound is
sounding. In the display
“DOOR ALARM” and a red
back light are flashing.
Freezer section door and/or
fridge section door open
for too long.
Please look at the section
“Control and information
system”. Do not leave the
doors open longer than
necessary.
Interior illumination does
not function.
Light bulb is defective.
Important: The interior
lighting switches off auto-
matically after 7 minutes.
Please refer to "Replacing
the Light Bulb" section.
Water on the floor or on
storage shelves.
Water drain hole is
blocked.
See the "Maintenance and
Cleaning" section.
Heavy build up of frost,
possibly also on the door
seal.
Door seal is not air tight
(possibly after changing
over the hinges).
Carefully warm the leak-
ing sections of the door
seal with a hair dryer (not
hotter than approx. 50 °C).
At the same time shape the
warmed door seal by hand
such that it sits correctly.
The compressor does not
start immediately after
changing the temperature
setting or the operating
mode.
This is normal, no error has
occurred.
The compressor starts after
a period of time.
Noise Appliance is not level.
Readjust the front levelling
feet.
Refer to Normal Operating
Sounds