User manual
performance, if the appliance is
positioned below an overhanging wall
unit, the minimum distance between the
top of the cabinet and the wall unit must
be at least 100 mm . Ideally, however, the
appliance should not be positioned
below overhanging wall units. Accurate
levelling is ensured by one or more
adjustable feet at the base of the
cabinet.
A
B
100 mm
min
20 mm
9.3 Electrical connection
• Before plugging in, ensure that the
voltage and frequency shown on the
rating plate correspond to your
domestic power supply.
• The appliance must be earthed. The
power supply cable plug is provided
with a contact for this purpose. If the
domestic power supply socket is not
earthed, connect the appliance to a
separate earth in compliance with
current regulations, consulting a
qualified electrician.
• The manufacturer declines all
responsibility if the above safety
precautions are not observed.
• This appliance complies with the
E.E.C. Directives.
9.4 Rear spacers
You can find the two spacers in the bag
with documentation.
1. Release the screw.
2. Engage the spacer below the screw.
3. Turn the spacer to the right position.
4. Tighten again the screws.
2
4
3
1
9.5
Levelling
Accurate levelling prevents the vibration
and noise of the appliance during
operation.
To adjust the heigh of the appliance
loosen or tighten the two adjustable
front feet.
9.6 Installation of the
CLEANAIR CONTROL filter
CAUTION!
The filter should be handled
carefully so fragments do
not loosen from the surface.
Make sure that the air lever
flap is closed to obtain
proper function.
The CLEANAIR CONTROL filter is an
active carbon filter which absorbs bad
odors maintain the best flavour and
aroma for all foodstuffs without risk of
odor cross contamination.
On delivery the carbon filter is in a plastic
bag to preserve performance.
1. Open the air lever flap.
2. Take the filter out of the plastic bag.
ENGLISH
33