Installation
12 818 19 80-00/7
Electrical Connection
Before initial start-up, refer to the appliance rating plate to ascertain if
supply voltage and current values correspond with those of the mains
at the installation location.
e.g.: AC 220 ... 240 V 50 Hz or
220 ... 240 V~50 Hz
(i.e. 220 to 240 volts alternating current, 50 Hertz)
The rating plate is inside the appliance on the left.
A correctly installed, earthed socket is required for the electrical supply.
The supply must have a fuse rating of at least 10 Amps.
If the socket is not accessible once the appliance is built in, the electri-
cal installation must include suitable means of isolating the appliance
from the mains (e.g. fuse, cut-out, current trip or similar with a mini-
mum contact separation of 3 mm).
Installation of the carbon filter
On delivery the carbon filter is placed
in a plastic bag to secure the length of
life of the carbon filter. The filter
should be placed behind the grill
before the cabinet is turned on.
0 1. The cover can be opened by simultane-
ously pressing the lever on the right of
grill (1) and turning the cover outward
(2).
2. The carbon filter is then mounted in
the slot found in the back of the cover
(3).
1
The filter should be handled carefully
so fragments donĀ“t loosen from the