User manual

To decrease or increase the power
level:
1. Deactivate the hob.
2. Touch for 3 seconds. The display
comes on and goes off.
3. Touch
for 3 seconds. or
comes on.
4. Touch . P0 comes on.
5. Touch / of the Timer to set the
power level.
Power levels
Refer to “Technical information” chapter.
P0 — 7200 W
P1 — 1500 W
P2 — 2000 W
P3 — 2500 W
P4 — 3000 W
P5 — 3500 W
P6 — 4000 W
P7 — 4500 W
P8 — 5000 W
P9 — 6000 W
CAUTION!
Make sure that the selected
power fits to the house
installation fuses.
4.12 Power management
function
Cooking zones are grouped
according to the location and number
of the phases in the hob. See the
illustration.
Each phase has a maximum electricity
loading of 3700 W.
The function divides the power
between cooking zones connected to
the same phase.
The function activates when the total
electricity loading of the cooking
zones connected to a single phase
exceeds 3700 W.
The function decreases the power to
the other cooking zones connected to
the same phase.
The heat setting display of the
reduced zones changes between two
levels.
Power management function with
Power limitation function
When you set the Power limitation
function to 4.5 kW or less, power of the
hob is divided between all cooking
zones.
When you set the Power limitation
function to more than 4.5 kW, power of
the hob is divided between two cooking
zones in a pair.
5.
HINTS AND TIPS
WARNING!
Refer to Safety chapters.
5.1 Cookware
For induction cooking zones
a strong electro-magnetic
field creates the heat in the
cookware very quickly.
ENGLISH 11