top hat nut assembly
fully screwed down
turn top
hat nut
anticlockwise
and remove
configuration for
natural gas
HG
F
E
configuration
for LPG
If the regulator works incorrectly:
Adjust of upstream regulator if the
outlet and inlet pressure is to slow or
an upstream regulator or valve with
insufficient flow capacity present in
the gas supply line.
Check again the inlet and outlet
pressure, the inlet pressure have to
have 2.75 - 7kPa.
Check if the insert is fitted correctly.
Check if the turret screw is fully
screwed down.
Check if the inlet and outlet is
orientated correctly the arrow on the
base of the regulator indicates the
direction of gas flow.
If the regulator still does not
work correctly contact the
After Sales Service.
4.4 Adjustment of minimum
level
To adjust the minimum level of the
burners:
1. Light the burner.
2. Turn the knob on the minimum
position.
3. Remove the knob.
4. With a thin screwdriver, adjust the
bypass screw position (A).
A
5. If you change:
from Natural Gas 1kPa to LPG,
fully tighten the bypass screw in.
from LPG to Natural Gas 1kPa,
undo the bypass screw
approximately 1/4 of a turn (1/2 of
a turn for Multi Crown burner).
WARNING!
Make sure the flame does
not go out when you quickly
turn the knob from the
maximum position to the
minimum position.
4.5 Electrical connection
The appliance is supplied with a
standard 7.5 Amp service cord
terminated by a 3-pin plug for
connection to a standard household
socket. The electrical supply is required
to power the electronic ignition system.
To disconnect the electrical
power supply, it is necessary
to service. After installation,
the power point should be
accessible according to local
wiring regulations.
Make sure that the rated voltage and
type of power on the rating plate
agree with the voltage and the power
of the local power supply.