User manual

TOTAL POWER: G20 (2H) 20 mbar = 13 kW
G30 (3+) 28-30 mbar = 931 g/h
G31 (3+) 37 mbar = 914 g/h
Electric supply: 230 V ~ 50 Hz
supply, 3 core flexible cable with
non rewireable plug fitted with a 3 amp car-
tridge fuse
Category: II2H3+
Gas connection: G 1/2"
Gas supply: G20 (2H) 20 mbar
Appliance class: 3
By-pass diameters
Burner Ø By-pass in 1/100 mm
Auxiliary 28
Semi-rapid 32
Rapid 42
Triple Crown 56
Gas burners
BURNER
NORMAL
POWER
REDUCED
POWER
NORMAL POWER
NATURAL GAS
G20 (2H) 20 mbar
LPG
(Butane/Propane) G30/G31 (3+)
28-30/37 mbar
kW kW
inj. 1/100
mm
m³/h
inj. 1/100
mm
G30
28–30
mbar
G31
37 mbar
g/h g/h
Auxiliary 1.0 0.33 70 0.095 50 73 71
Semi-rap-
id
2.0 0.45 96 0.190 71 145 143
Rapid
3.0 (natural
gas)
2.8 (LPG)
0.75 119 0.286 86 204 200
Triple
Crown
4.0 1.4 146 0.381 98 291 286
ENVIRONMENT CONCERNS
The symbol on the product or on its packaging indicates that this product may not be
treated as household waste. Instead it should be taken to the appropriate collection point
for the recycling of electrical and electronic equipment. By ensuring this product is
Environment concerns