User manual

To replace the connection
cable use only H03V2V2-F
T90 or equivalent type.
Make sure that the cable
section is applicable to the
voltage load and the
working temperature. The
yellow/green earth wire (B)
must be approximately 2 cm
longer than the live and
neutral wire (A).
A B
1.
Connect the green and yellow (earth)
wire to the terminal which is marked
with the letter 'E', or the earth
symbol , or coloured green and
yellow.
2. Connect the blue (neutral) wire to the
terminal which is marked with the
letter 'N' or coloured blue.
3. Connect the brown (live) wire to the
terminal which is marked with the
letter 'L'. It must always be
connected to the network phase.
There must be no cut or stray strands
of wire present. The cord clamp must
be correctly attached to the outer
sheath.
8.8 Assembly
1.
2.
3.
min. 55 mm
min. 650 mm
560 mm
min. 200 mm
30 mm
4
80
mm
min. 600 mm
4.
50 mm
400 mm
ENGLISH