User manual

9.4 Gas burners for NATURAL GAS G20/G25 20/25 mbar (BE) -
G20 20 mbar (LU)
BURNER NORMAL POWER kW MINIMUM POWER
kW
INJECTOR MARK
Triple Crown 4,0 1,4 146
Semi-rapid 2,0 0,45 96
Auxiliary 1,0 0,33 70
9.5 Gas burners for LPG G30/G31 28-30/37 mbar
BURNER NORMAL
POWER kW
MINIMUM
POWER kW
INJECTOR
MARK
NOMINAL GAS FLOW g/h
G30 28-30
mbar
G31 37 mbar
Triple Crown 4,0 1,4 98 291 286
Semi-rapid 2,0 0,45 71 145 143
Auxiliary 1,0 0,33 50 73 71
10. ENERGY EFFICIENCY
10.1 Product information according to EU 66/2014
Model identification HG654440SM
Type of hob Built-in hob
Number of gas burners 4
Energy efficiency per gas burner
(EE gas burner)
Left rear - Semi-rapid 56.2%
Right rear - Triple Crown 52.0%
Right front - Auxiliary not applicable
Left front - Semi-rapid 56.2%
Energy efficiency for the gas hob
(EE gas hob)
54.8%
EN 30-2-1: Domestic cooking appliances burning gas - Part 2-1 : Rational use of
energy - General
10.2 Energy saving
Before use, make sure that the burners and pan supports are assembled correctly.
Use cookware with diameters applicable to the size of burners.
Center the pot on the burner.
When you heat up water, use only the amount you need.
If it is possible, always put the lids on the cookware.
When the liquid starts to boil, turn down the flame to barely simmer the liquid.
ENGLISH
35