User manual

A
A)
Rigid copper pipe or flexible pipe of
stainless steel
8.5 Replacement of the
connection cable
To replace the connection cable use on-
ly H05V2V2-F T90 or equivalent type.
Make sure that the cable section is appli-
cable to the voltage and the working
temperature. The yellow/green earth
wire must be approximately 2 cm longer
than the brown (or black) phase wire.
8.6 Building In
min.
55 mm
min.
650 mm
560 mm
480 mm
min.
200 mm
30 mm
B
A
A)
supplied seal
B)
supplied brackets
CAUTION!
Install the appliance only on a
worktop with flat surface.
If you install the hob under a
hood, please see the installation
instructions of the hood for the
minimum distance between the
appliances.
8.7 Possibilities for insertion
Kitchen unit with door
The panel installed below the hob must
be easy to remove and let an easy ac-
cess in case a technical assistance inter-
vention is necessary.
min 20 mm
(max 150 mm)
30 mm
60 mm
B
A
A)
Removable panel
B)
Space for connections
Kitchen unit with oven
The electrical connection of the hob and
the oven must be installed separately for
safety reasons and to let easy remove
oven from the unit.
ENGLISH 13