Operation Manual

Water hardness
Water softener
adjustment
German
degrees
(°dH)
French
degrees
(°fH)
mmol/l Clarke
degrees
Manual Elec-
tronic
43 - 46 76 - 83 7.6 - 8.3 53 - 57
2
1)
9
37 - 42 65 - 75 6.5 - 7.5 46 - 52
2
1)
8
29 - 36 51 - 64 5.1 - 6.4 36 - 45
2
1)
7
23 - 28 40 - 50 4.0 - 5.0 28 - 35
2
1)
6
19 - 22 33 - 39 3.3 - 3.9 23 - 27
2
1)
5
1)
15 - 18 26 - 32 2.6 - 3.2 18 - 22 1 4
11 - 14 19 - 25 1.9 - 2.5 13 - 17 1 3
4 - 10 7 - 18 0.7 - 1.8 5 - 12 1 2
< 4 < 7 < 0.7 < 5
1
2)
1
2)
1)
Factory position.
2)
Do not use salt at this level.
You must adjust the water soft-
ener manually and electronically.
Manual adjustment
Turn the water hardness dial to the posi-
tion 1 or 2.
Electronic adjustment
1. Press the on/off button to activate
the appliance. Make sure that the ap-
pliance is in setting mode, refer to
‘Setting and starting a programme’.
2. Press and hold touchpads (4) and (5)
at the same time until the indicators
of touchpads (3), (4), (5) and (6) flash.
3. Press touchpad (3).
The indicators of touchpads (4), (5)
and (6) go off.
The indicator of touchpad (3) con-
tinues to flash.
The acoustic signals operate, e.g.
five intermittent acoustic signals =
level 5.
The display shows the current set-
ting of the water softener, e.g.
= level 5.
4. Press touchpad (3) again and again
to change the setting.
5. Deactivate the appliance to confirm
the setting.
26