User manual
CONNECTING TO MAINS TERMINAL
Make connection as shown in Fig. 7 by
proceeding as follows:-
Preform wires to the appropriate shape to suit
fitting into the mains terminal block.
Strip inner insulation on wires using
wirestrippers.
Twist the bared wires using pliers.
Cut bared wires 10mm away from the end of
the inner insulation. Where uninsulated Earth
wires are used ensure they are suitably
sheathed to leave 10mm bare wire to fit into
the terminal.
Clamp bare wires into the relevant terminal and
check they are held by tugging each one in turn.
Clamp the mains cable securely ensuring 5mm
of the outer insulation is inside the terminal
block and that the wires are not taut but not so
slack as to cause any damage. See Fig. 7.
Place fuse/miniature circuit breaker in circuit
and switch on at mains.
CONNECTING TO A HOB OR COOKER
POINT
Either follow in general terms the instructions
for connecting to the terminal block or refer to
the hob suppliers installation instructions.
CHECKING ELECTRICAL
CONNECTIONS
Correct electrical connection can be confirmed
when switching on the appliance as the timer
will be flashing.
NOTE: HOUSE CIRCUIT
Earth leakage and continuity tests must be carried
out before the appliance is connected to the mains
supply and re-checked after fitting.
45
WARNING: This appliance must be
earthed.
Feed the cable through the cabinet and
arrange to route the cable away from
the appliance which may become hot.
Fig.7