WARNING!
Installation into flammable mate-
rial must agree with NIN SEV
1000 (Association of Cantonal
Fire Insurers) fire protection
guidelines and regulations.
CAUTION!
Make sure the cable is free when
you move the appliance.
1.
Push the cooker into the recess so
that it is flush with the surrounding
units.
AB
min. 20
10
20
A
2.
Use at least 2 screws to fix the appli-
ance on both sides (Detail A).
WARNING!
When installing next to a wood-
fuelled boiler, a heatproof and
heat-insulating plate must be
mounted at the height of the ap-
pliance and at least 30 cm deep.
12.3 Electrical connection
Use a power cable of H05VV-F or higher.
Connect the appliance to a socket sup-
ply line. If there is no socket supply line,
the electrical installation must have an
isolation device which lets you discon-
nect the appliance from the power sup-
ply. The isolation device must have a
contact opening width of minimum 3
mm (in reference to NIN SEV 1000). The
customer must have a socket for the
electrical connection that is accessible
and outside the coordination room. The
length of the connection cable must be
approximately 120 cm with lines connec-
ted directly to the power supply.
L2
L1PE
400V 2 ~
400V
123
45
Only a qualified person can con-
nect the appliance to the elec-
tricity supply.
1.
Do the electrical connections as in
the connection illustration.
Phase definitions: L1, L2 (or R, S).
2.
Secure the cord grip.
CAUTION!
If service is required always dis-
connect the appliance from the
power supply.