User manual

CAUTION!
Make sure you install the
anti-tilt protection at the
correct height.
Make sure that the surface behind the
appliance is smooth.
1. Set the correct height and area for
the appliance before you attach the
anti-tilt protection.
2. Install the anti-tilt protection 77 mm
down from the top surface of the
appliance and 49 mm from the left
side of the appliance into the circular
hole on the bracket. See the
illustration. Screw it into the solid
material or use applicable
reinforcement (wall).
3. You can find the hole on the left side
at the back of the appliance. See the
illustration. Lift the front of the
appliance (1) and put it in the middle
of the space between the cupboards
(2). If the space between the bench
cupboards is larger than the width of
the appliance, you must adjust the
side measurement to centre the
appliance.
1
2
49 mm
77 mm
14.5 Electrical installation
WARNING!
The manufacturer is not
responsible if you do not
follow the safety precautions
from Safety chapters.
This appliance is supplied without a main
plug or a main cable.
Applicable cable types: H07 RN-F, H05
RN-F, H05 RR-F, H05 VV-F, H05 V2V2-F
(T90), H05 BB-F.
15.
ENERGY EFFICIENCY
15.1 Product information for hob according to EU 66/2014
Model identification 69476VS-MN
Type of hob Hob inside Freestanding Cooker
Number of cooking zones 4
Heating technology Radiant Heater
Diameter of circular cooking
zones (Ø)
Left front
Left rear
Right front
21.0 cm
14.5 cm
14.5 cm
Lenght (L) and width (W) of
non circular cooking zone
Right rear L 26.5 cm
W 17.0 cm
www.aeg.com40