User's Manual

ADD-INS-PE3LR-CARE-ENG-31 Subject to change without noce
ADVEEZ, Bat MEAS - Impasse Jeanne Benozzi CS 83163 email: contact@adveez.com
31027 Toulouse Cedex 3 FRANCE Phoenix, AZ USA
+33(0)582082193 +1 602-549-7898
3
www.adveez.com
ands-free Access Control System PE3LR
SYSTEM COMPONENTS PE3LR / AD-CARE
INTERNAL READER—PE3LR-C / AD-CARE STAND-ALONE CONTROLLER
EXTERNAL READER / ANTENNA PE3LR-E
ORGANEEZ SUPERVISED ACCESS CONTROL MANAGEMENT (not described in present doc.)
64000 event history / 10000 users / 128 readers / TCP-IP-R-485-Radio network
SYSTEM COMPONENTS— PE3LR/AD-CARE controller & PE3LR external antenna—FCC ID: R8T-PE3LR-C
Hands-free Access Control – 1 access point
1024 cards in stand-alone version (64000 users in network version)
Program cards directly with Master Card (PE3LR-MC) or management soware via PC– USB Cable
The Internal Reader funcon PE3LR-C Door Controller allows:
-Seng hands-free access or proximity (125 kHz) control in the secured zone on the external side without
adding an addional Reader
-Enrolling badges directly via the controller
-Sensing movement direcon between PE3LR-C internal Reader and PE3LR-E external Reader
-Connecng to ADVEEZ supervised access control system in a wired RS485 mode (Ref. P3LR-C-MC) or wire-
less (ref. PE3LR-C-WL)
-connecng to exisng third party access control systems via Wiegand output
-connecng to nurse call systems (AD-CARE version)
- Waterproof and robust for outdoor installaon
- addional Hands Free / detecon zone
- ADVEEZ PE3LR-T Hands-free tag reading
- 125 KHz EM4100, 4200, 4450 Marin card reading
Access Control Systems / Wander monitoring
PE3LR-PLG-WANDER-MONITORING (AD-CARE)
- Enroll & Delete cards / wrist
- Download logged events
- Congure access control (relay output) & alarm clear-
PE3LR-PLG (PE3LR ACCESS CONTROL)
- Enroll & Delete cards
- Download logged events
- Congure access control (relay output)
STAND ALONE CONFIGURATION SOFTWARE (not described in present document)
This device (FCC ID : R8T-PE3LR-C) complies with part 15 of the FCC Rules. Operation is subject to the following two condi-
tions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation”
WARNING STATEMENT FOR MODULE:
Because of the power level and grant condions of the Zig-Bee module, the 20cm separaon distance warning statement is need-
ed. Please see below.: The antenna(s) used for this transmier must be installed to provide a minimum separaon distance of
20cm, and must not be co-located or operang in conjuncon with any other antenna or transmier.
FULL FUNCTION BENEFIT FROM PE3LR / AD-CARE WILL BE OBTAINED WITH FOLLOWING SOFTWARE