Owner's manual

ADS Environmental Services ADS Spider User Manual
Page 97
Numeric
Identifier
Range Text Comment
STATE
80 + IN#
80 - 87
Numeric value
of event
counter at the
time of the
event
Event input log
record + event
counter
100 + 2*CNT#
+ STATE
100
115
CNx=y Control change
140 + IN# 140 -
147
Numeric value
of event
counter at
midnight
Event input midnight
check (no event
occurred)
160 + IN#
160 -
167
Numeric value
of daily rain
total at the
time of the
event
Daily rain input log
record + total
180 + IN# 180 -
187
Numeric value
of daily rain
total at
midnight
Daily rain input
midnight check (no
event occurred)
200 + AL# 200
207
Alarm x Alarm activation
280 + AL# 280 -
287
Almx RST Alarm reset
300 + 10*AL#
+ SEQ
300 -
379
SMSxy OK Text message alarm
transmission OK
500 + 10*AL#
+ SEQ
500 -
579
SMSxy NG Text message alarm
transmission failed
700 + AL# 700
707
SMS ALxK Text message
command
acknowledge an
alarm