AC 12 10 8 6 MAN final 3/2/05 12:55 PM Page 1 SLIDER CASEMENT ROOM AIR CONDITIONER Use and Care Manual CORREDIZO MARCO DE AIRE ACONDICIONADO PARA HABITACIONES Manual de Uso y Mantenimiento Thank you for purchasing an Admiral® room air conditioner. Please read this “Use and Care Manual” carefully before installing and using this appliance. Keep this manual for future reference. Muchase gracias por comprar un aire acondicionado Admiral®.
AC 12 10 8 6 MAN final 3/2/05 12:55 PM Page 2
AC 12 10 8 6 MAN final 3/2/05 12:55 PM Page 3 TABLE OF CONTENTS Page Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Parts Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Air Conditioner Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4 Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AC 12 10 8 6 MAN final 3/2/05 12:55 PM Page 4 INTRODUCTION Thank you for choosing this room air conditioner to cool your home. This USE AND CARE MANUAL provides information necessary for the proper care and maintenance of your new room air conditioner. If properly maintained, your air conditioner will give you many years of trouble free operation. To avoid installation difficulties, read instructions completely before starting.
AC 12 10 8 6 MAN final 3/2/05 12:55 PM Page 5 AIR CONDITIONER SAFETY Your safety and the safety of others are very important. We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages. This is the SAFETY ALERT SYMBOL. This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.
AC 12 10 8 6 MAN final 3/2/05 12:55 PM Page 6 INSTALLATION REQUIREMENTS • The portable air conditioner should be connected to a 115 V, 60 Hz, 15- or 20-amp fused 3-prong grounded outlet. • The use of a time-delay fuse or time-delay circuit breaker is recommended. Power Supply Cord NOTE: Your unit’s device may differ from the one shown. • All wiring must comply with local and national electrical codes and be installed by a qualified electrician.
AC 12 10 8 6 MAN final 3/2/05 12:55 PM Page 7 ELECTRICAL SPECIFICATIONS 1. All wiring must comply with local and national electrical codes and must be installed by a licensed electrician. Once you have any questions regarding the following instructions, contact a licensed electrician. Electric Shock Hazard If the air conditioner has a serial plate rating of 115 volts and up to and including 7.5 amps the unit maybe on a fuse or circuit breaker with other devices.
AC 12 10 8 6 MAN final 3/2/05 12:55 PM Page 8 TIPS BEFORE INSTALLATION NOTE: Save the shipping carton and packing materials for future storage or transport of the unit. Please check the contents of hardware kit against the corresponding model check list, prior to installation of the unit. See lists below.(Fig.A) Your Room Air Conditioner unit is designed to be highly efficient and save energy. Follow these recommendations for greater efficiency. 1.
AC 12 10 8 6 MAN final 3/2/05 12:55 PM Page 9 INSTALLATION INSTRUCTIONS Sliding Window Installation A 7/16"Screws Support platform Support angle Leveling bolt 1.Choose the installation site. It is imperative that the window frame assembly and the side of the structure are adequate to support the weight of the unit. Reinforce if necessary. 2.Slide open one window sash to install support platform. 3.Loosely attach support angle to bottom of support platform using two 7/16" screws, washers and nuts.
AC 12 10 8 6 MAN final 3/2/05 12:55 PM Page 10 INSTALLATION INSTRUCTIONS Installation 12.Install speed clips on top and bottom inside edge of window to provide locking. (See fig. E) 13.Using supplied foam, cut to proper length, insert between inside window sash and outside window.(See fig. E) 14.Place top retainer on top edge of filter panel, then place the bottom edge of filler panel into groove of bottom retainer (mounted on unit).
AC 12 10 8 6 MAN final 3/2/05 12:55 PM Page 11 OPERATING INSTRUCTIONS 4.CONTROL PANEL(Only for electronic models) Caution: If air conditioner is shut off, wait a minimum of three minutes before restarting Control Functions Air Exchanger: Circulates fresh air and helps remove stale air when in the open position. Maximum air circulation and cooling occur when in the closed position.
AC 12 10 8 6 MAN final 3/2/05 12:55 PM Page 12 OPERATING INSTRUCTIONS ➤REMOTE CONTROL Remote control 1 Power BUTTON 1 2 7 Power Timer Mode Power Saver Auto 4 Mid Fan Speed High 3 The appliance will be started when it is energized or will be stopped when it is in operation, if you press this button. 8 9 2 5 3 6 Low _ Mode BUTTON Used to select the operation mode. 4 + Temp/Time BUTTONS Used to set room temperature in COOLING mode or used to set time in Timer mode.
AC 12 10 8 6 MAN final 3/2/05 12:55 PM Page 13 OPERATING INSTRUCTIONS ➤REMOTE CONTROL Remote control How to Insert the Batteries Remove the battery cover according to the arrow direction. Insert new batteries making sure that the (+) and (-) of battery are matched correctly. Reattach the cover by sliding it back into position. Note: Use 2 LR6 AA(1.5volt) batteries. Do not use rechargeable batteries. Replace batteries with new ones of the same type when the display becomes dim.
AC 12 10 8 6 MAN final 3/2/05 12:55 PM Page 14 CARE AND MAINTENANCE When servicing the air conditioner, be sure to turn the mode switch to the "OFF" position and disconnect the power cord from the electrical outlet. 1. DOT NOT use gasoline, benzine, thinner or other chemicals on the air conditioner as these substances may cause damage to the paint finish and deformation of plastic parts. 2.
AC 12 10 8 6 MAN final 3/2/05 12:55 PM Page 15 TROUBLESHOOTING GUIDE Frequently, a problem is minor and a service call may not be necessary, use this troubleshooting guide for a possible solution. PROBLEM Air conditioner will not operate POSSIBLE CAUSE No power to the unit. SUGGESTED SOLUTION Check connection of power cord to power source. Check fuse or circuit breaker. Set MODE knob to position other than "OFF". Inefficient or no cooling Dirty air filter. Clean or replace air filter.
AC 12 10 8 6 MAN final 3/2/05 12:55 PM Page 16 WARRANTY 5 YEAR FULL WARRANTY This product is warranted for 5 years from the date of original purchase. Any part which fails in materials or workmanship will be replaced within the warranty period. This warranty covers in home service. A copy of your proof of purchase, with date of purchase and product name included, is required to arrange this service repair.
AC 12 10 8 6 MAN final 3/2/05 12:55 PM Page 17 Introducción TABLE OF CONTENTS Gracias por elegir este aire acondicionado para enfriar su hogar. Este MANUAL DE USO Y MANTENIMIENTO proporciona la informaci n necesaria para cuidar y mantener en forma adecuada su nuevo aire acondicionado. Funcionar sin problemas durante muchos anos si le brinda el mantenimiento apropiado. Para evitar problemas al instalarlo, lea completamente las instrucciones antes de comenzar.
AC 12 10 8 6 MAN final 3/2/05 12:55 PM Page 18 TABLE OF CONTENTS Especificaciones eléctricas 1. Todos los cables deben cumplir con los c digos el ctricos locales y nacionales y los debe instalar un electricista licenciado. Si tiene preguntas relacionadas con las siguientes instrucciones, comun quese con un electricista licenciado. Peligro de Descarga El ctrica Si el r tulo del aire acondicionado indica 115 voltios y hasta 7.
AC 12 10 8 6 MAN final 3/2/05 12:55 PM Page 19 TABLE OF antes Consejos CONTENTS de la instalación NOTA: conserve la caja de la unidad y los materiales de empaque para almacenarla o transportarla en el futuro. Antes de instalar la unidad compare el contenido del juego de herrajes con la lista de control del modelo correspondiente. Consulte las siguientes listas (Fig. A). Su unidad de Aire Acondicionado para Habitaciones se ha disenado para lograr un alto rendimiento y ahorrar energ a el ctrica.
AC 12 10 8 6 MAN final 3/2/05 12:55 PM Page 20 TABLE OF CONTENTS Instrucciones de Instalación Instalaci n en Ventanas Deslizantes de Metal A Tornillos de 7/16" Plataforma de montaje Soporte en ngulo Perno de nivelaci n B Dos tornillos autorroscantes de 1" de largo Plataforma de montaje ensamblada Gu a inferior de la ventana C Sello Sujetador superior Panel de relleno Correderas Sello m s corta La instalaci n mencionada debe ser permanente y si se realiza en un apartamento o en una propiedad de
AC 12 10 8 6 MAN final 3/2/05 12:55 PM Page 21 TABLE OF CONTENTS Instrucciones de Instalación Instalaci n D Plataforma de montaje Orificios perforados Centro Barra inferior (en el fondo de gabinete) 4.9 4.9 Canal del marco de la ventana Orificios perforados Tornillos de 3/8" de largo E Trabas de sujeci n Canal Espuma Precauci n: no obstruya la circulaci n de aire por las persianas externas del gabinete. 12.
AC 12 10 8 6 MAN final 3/2/05 12:55 PM Page 22 TABLE OF CONTENTS Instrucciones de Operación Este aire acondicionado se puede operar f cilmente con los botones del panel de control as como tambi n con el control remoto. Precauci n: Espere tres minutos antes de volver a comenzar Panel de Control Funciones del Control Intercambiador de Aire: cuando est abierto hace que circule el aire fresco y elimina el aire viciado. El m ximo enfriamiento y circulaci n de aire se producen cuando est cerrado.
AC 12 10 8 6 MAN final 3/2/05 12:55 PM Page 23 TABLE OF CONTENTS Instrucciones de Operación ➤Control remoto Control remoto 1 Bot n Power (Encendido/Apagado) El aparato se encender si est apagado o apagar cuando est en operaci n, si oprime este bot n. 1 2 7 Power Timer Mode Power Saver Auto 4 Mid Fan Speed High 3 2 Bot n Mode (Modo) 8 Utilice este bot n para seleccionar el modo de operaci n. 9 3 Bo t n + - 5 Botones de ajuste de temperatura oprima para ajustar la temepratura del cuarto.
AC 12 10 8 6 MAN final 3/2/05 12:55 PM Page 24 TABLE OF CONTENTS Instrucciones de Operación ➤Control remoto Control remoto Colocai n de las pilas Retire la tapa de las en el sentido de la flecha. Introduzca las pilas nuevas,con cuidado de que coincidan los polos(+)y(-). Vuelva a instalar la tapa,desliz ndola otra vez a su posici n. Nota: Utilice pilas 2 LR6 AA(1.5V). No utilice pilas recargables.Sustituya las pilas por otras nuevas del mismo tipo cuando la pantalla aparezca atenuada.
AC 12 10 8 6 MAN final 3/2/05 12:55 PM Page 25 TABLE OFy CONTENTS Cuidado Mantenimiento Cuando repare el aire acondicionado, aseg rese de colocar la perilla de modo en OFF y luego desconectar el cable de alimentaci n del tomacorriente el ctrico. 1. NO utilice gasolina, bencina, disolvente u otros productos qu micos en el aire acondicionado, ya que estas sustancias pueden danar el acabado de pinturay deformar las piezas de pl stico. 2.
AC 12 10 8 6 MAN final 3/2/05 12:55 PM Page 26 TABLE Guá para OF la CONTENTS Solución de Problemas Generalmente los problemas son sencillos y es probable que no sea necesario llamar a un t cnico. Esta gu a puede ayudarlo a resolverlos. PROBLEMA El aire acondicionado no funciona CAUSA POSIBLE La unidad no recibe suministro el ctrico. SOLUCI N SUGERIDA Verifique si el cable de alimentaci n e st conectado al tomacorriente. Verifique el fusible o el cortacircuito.
AC 12 10 8 6 MAN final 3/2/05 12:55 PM Page 27 TABLE OF CONTENTS Garantía GARANTIA COMPLETA DE 5 ANOS Este producto se garantiza por 5 anos a partir de la fecha de la compra original. Cualquier parte que falle en materiales o la ejecuci n ser substituida dentro del per odo de la garant a. Esta garantia incluye servicio a domicilio. Una copia de su prueba de la compra, con la fecha de la compra del producto incluida, se requiere para acordar esta reparaci n del servicio.
AC 12 10 8 6 MAN final 3/2/05 12:55 PM Page 28 © 2005 Admiral , Kelon Air Conditioner Co., and Kelon USA, Inc. All rights reserved.