* Exceeding the distance of copper-clad cable will result in the attached RAU becoming non-functional. If
the distance of a cable run is at its maximum and is of concern, TE recommends the use of solid copper
cable to ensure successful operation.
A.2 Fiber Optical Cables
Connects the Main Hub to Expansion Hub(s)
Transmits (downlink) and receives (uplink) optical signals
Carries configuration and status information
Use industry-standard 62.5µm/125µm MMF or Corning SMF-28 fiber, or equiva-
lent.
SC/APC (angle-polished) connectors are required throughout the fiber network
(port-to-port), including fiber distribution panels
Table A-2 System Gain (Loss) Relative to CATV Cable Length for 800/900/1900
RAUs
Cable
Type
Comm-
Scope
Part
Number
Plenum
Rated
Solid
Copper
Conductor
Copper
Clad
Conductor
Zero-loss
RF
Maximum
Length
(meters)
Distance
Where
RF is
10dB
Below
Input RF
(meters)
RG-59
2065V Yes X 150 210
2022V Yes X 80 80*
5572R No X 70 70*
5565 No X 150 210
RG-6
2279V Yes X 170 230
2275V Yes X 115 115*
5726 No X 110 110*
5765 No X 170 230
RG-11
2293K Yes X 275 375
2285K Yes X 240 240*
5913 No X 240 240*