User's Guide

Table Of Contents
Expansion Hub Specifications
4-10 InterReach Fusion Installation, Operation, and Reference Manual
CONFIDENTIAL D-620610-0-20 Rev B
4.5 Expansion Hub Specifications
Table 4-4 Expansion Hub Specifications
Specification Description
Enclosure Dimensions (H
× W × D) 89 mm x 438 mm x 381 mm
(3.5 in. x 17.25 in. x 15 in.) 2U
Weight < 6.6 kg (< 14.5 lb.)
Operating Temperature
0° to +45°C (+32° to +113°F)
Non-operating Temperature
–20° to +85°C (–4° to +185°F)
Operating Humidity, non-condensing 5% to 95%
CATV Connectors
a
a. It is important that you use only recommended CATV 75 Ohm cable with quality F connectors.
8 F, female (CATV - 75 Ohm)
Fiber Connectors
b
b. It is critical to system performance that only SC/APC fiber connectors are used throughout the fiber network, including
fiber distribution panels.
1 Pair, SC/APC
LED Alarm and Status Indicators Unit Status (1 pair):
•Power
E-Hub Status
Fiber Link Status (1 pair):
•DL Status
•UL Status
Port Status (1 pair per CATV port):
Link/RAU
External Alarm Connector (contact sense
monitor)
1 9-pin D-sub, female
AC Power (Volts) (47–63 Hz) Rating: 115/230V AC, 6/3A, 50-60 Hz
Operating Range: 90-132V AC/170-250V AC auto-ranging
Power Consumption (W) 4 RAUs: 305 typical
8 RAUs: 530 typical
MTBF 54,477 hours