User's Manual

Table Of Contents
C-2 InterReach Fusion Wideband Installation, Operation, and Referencer Manual
CONFIDENTIAL D-620616-0-20 Rev A
cause. Actions are listed in the order that they should be performed; not all actions
may need to be done.
NOTE: If you have a red STATUS LED without a fault message, it probably
indicates that the unit is locked out.
Table C-1 Fault Messages for Fusion Wideband Main/SingleStar Hubs
Message
Number Description Reason/Action
{MF01} Software error occurred and recovered. If this happens repeatedly, replace the Hub.
{MF02} Software error occurred and recovered. If this happens repeatedly, replace the Hub.
{MF03} Software error occurred and recovered. If this happens repeatedly, replace the Hub.
{MF04} Software reset occurred and recovered,
or firmware download.
If this happens repeatedly, replace the Hub.
{MF05} Software error occurred and recovered. If this happens repeatedly, replace the Hub.
{MF06} Problem detected in the Hub. Internal
communication reset.
Contact LGC Wireless Support for more information.
{MF07} Hub power cycle. Hub power cycle.
{MF08} Internal communications failure. No internal communications in preceding 15 minutes.
{MF09} Hardware Reset. Commanded hardware power on reset
{MF10} Band not programmed. Use AdminBrowser to program the band.
{MF11} Hardware failure (DL Pilot PLL). Cycle power once. If fault persists, replace the Hub
{MF12} Hardware failure (DL Pilot Too High). Cycle power once. If fault persists, replace the Hub.
{MF13} Hardware failure (DL Pilot Too Low). Cycle power once. If fault persists, replace the Hub.
{MF14} Hardware failure (54 VDC). 54 VDC power supply is out of range, replace the Hub
{MF15} Hardware failure (RF VDC Power). Loss of DC power to RF circuits, replace the Hub.
{MF16} Self Lockout (All Bands). Hub has shutdown the system due to an internal fault.
System is offline.
{MF17} Hardware failure (DL PLL Band 1). Cycle power once. If fault persists, replace the Hub.
{MF18} Hardware failure (UL PLL Band 1). Cycle power once. If fault persists, replace the Hub
{MF19} Commanded Out-of-service (Band 1). Band 1 commanded out-of-service by User.
{MF20} Problem detected in the Hub. Contact LGC Wireless Support for more information.
{MF21} Problem detected in the Hub. Contact LGC Wireless Support for more information.
{MF22} Problem detected in the Hub. Contact LGC Wireless Support for more information.
{MF23} Problem detected in the Hub Contact LGC Wireless Support for more information.
{MF24} Problem detected in the Hub. Contact LGC Wireless Support for more information.
{MF25} Hardware failure (DL PLL Band 2). Cycle power once. If fault persists, replace the Hub.
{MF26} Hardware failure (UL PLL Band 2). Cycle power once. If fault persists, replace the Hub.
{MF27} Commanded Out-of-service (Band 2). Band 2 commanded out-of-service by User.
{MF28} Problem detected in the Hub. Contact LGC Wireless Support for more information.
{MF29} Problem detected in the Hub. Contact LGC Wireless Support for more information.
{MF30} Problem detected in the Hub. Contact LGC Wireless Support for more information.
{MF31} Problem detected in the Hub. Contact LGC Wireless Support for more information.