Specifications

50 IBM System z Personal Development Tool: Volume 3 Additional Topics
074 - IPL program contains a logic error (6)
075 - IPL program could not load a module (4,14,6)
076 - IPL found non-fullword relocatable address constant (6)
077 - SVC entry point cannot be resolved (6)
078 - Master catalog could not be opened (2,4,6)
07B - Required processor facility not available (19)
07C - Initialization error, configuration problem. (18,1,see Codes manual)
07D - IEASYSxx PARMLIB member is bad; in error (4)
07E - Unable to obtain LSQA storage for SVC (11,6)
081 - SYS1.NUCLEUS occupies more than one extent
082 - System joining sysplex needs maintenance
083 - Incorrect address in PSA (16)
084 - RTM error (17,6)
085 - ASM warm start problem (1,10,20)
087 - System removed from sysplex (normal situation)
088 - IPL: error in LOADxx or NUCLSTxx (18,4,6)
089 - NIP found an error in a UCB (6)
08A - WTO error going to wait state
08C - WLM has recurring error (6)
08E - SYSEVENT error (6)
08F - Failure rebuilding work queues (6)
09x - SPINLOOP problem (See Codes manual for more information)
0A1 - Excessive SPINLOOP unresolved (21)
0A2 - XCF encountered cross system problem
0A3 - Unable to join global GRS
0A4 - ETR problem
0A5 - HCD problem (remember: zPDT does not support dynamic reconfiguration)
0A7 - Insufficient ESQA or ECSA storage (11)
0B0 - Could not recognize IODF specified in LOADxx (18,1)
0B1 - LOADxx member problem (18,1)
0B2 - No devices in IODF (18, or you created a bad IODF)
0B3 - Incorrect information in IPL parameter
0B4 - UIM specified unidentified device number (22)
0E0 - SIGNAL failed during NIP (16)
0E1 - SIGP STOP failed because processor was not operational (16)
0E3 - Insufficient virtual storage to initialize CSA (4)
0E8 - During NIP, the machine check handler failed (6)
101 - Program in supervisor state requested too much SQA (6)
102 - Program in supervisor state requested more pages of SQA than available (6)
104 - While provessing ABEND SVC, program check occurred recursively (6)
110 - System detected hot I/O from device other than DASD (16; note MVS console
messages)
111 - System detected hot I/O on DASD device (16, note MVS console messages)
112 - System detected hot I/O on reserved DASD (16, note MVS console messages)
113 - Failure during channel path recovery (16)
114 - Previous error affected SMP operation. See manual.
115 - DASD containing paging dataset is unavailable. (10)
116 - During restart, detected missing interrupt for paging device (16)
11A - Error during SVC 26 (6)
201 - Failure while creating COMMTASK (6)
202 - During system initialization, creation of console communications failed (6)
204 - Error during allocation (6)
205 - Attempted to load a module that was not in LINKST (6)
206 - Sysplex initialization operator message prompt
5C7 - Error during processor or system termination (6)
A00 - DAT error for system address space (16,6)
A01 - Error on only online processor (16)
A18 - Unsolicited Device end on paging volume; AVR failed. (complex)
A19 - Can no longer perform I/O (16)
A1E - Time-of-day clock failed (16)