Manual

AMI Reference Manual
36
Characteristic Specification
Operating conditions
0° to 40° C (32° to 104° F)
25% to 85% relative humidity (non-condensing)
Storage conditions
-20° to 60° C (-4° to 140° F)
25% to 95% relative humidity (non-condensing)
115VAC ±10%
230VAC ±10%
47-63Hz
124mA (max.) @ 115VAC
62mA (max.) @ 230VAC
Input requirements:
Voltage
Frequency
Current
Fuse
200mA, 3AG, 250V SLO-BLO @ 115VAC
100mA, 3AG, 250V SLO-BLO @ 230VAC
4 Amps max. @ 230V AC
AMI output relay
contact ratings (J18)
FCC compliance
Part 15 of FCC rules for a class A
computing device
Compatibility
Compatible with ACU-RITE
®
MILLPWR
®
systems software versions 2.1.2 and 3.1.2 or later
Electrical Specifications
The installation location must be able to support the AMI operating and
electrical requirements listed below.
E-Stop Output ratings (J17)
14 Amps max. @ 230V AC
SCI Contact Specifications
(J1, J2 & J5)
0.5 Amps max @ 125V AC