User's Manual

Table Of Contents
MTU Instruction
for Severn Trent Water Meters
471-2052 - 6/9/2008
Purpose & Scope
This instruction provides wiring information for use in connecting a STAR MTU to Severn
Trent Water Meters.
Supplies and Tools Required
See Publication 471-2000, General
Installation and Wiring Guidelines for a
complete list of recommended tools and
supplies for MTU Installation.
Installation Procedure
Step 1 - Select a mounting location for
the MTU that will allow optimum signal
transmission, and install any needed
wiring. Be sure to follow all General
Installation and Wiring Guidelines as
outlined in Publication 471-2000.
Step 2 Connect the MTU cable to the
meter cable according to the table below.
MTU Cable Meter Cable
Red Red
Black Black
White Green
Step 3 – Make a final visual check of the
wiring from the MTU to the meter. Verify
that the cable routing is neat, secure and
professional.
Step 4 – Once installation and wiring are
complete, program the MTU using the
STAR Programmer Software and your
MTU Programmer.
Page 197