User Manual
104
English
“Maximum file size” Maximum size of the file in kByte (max. 800 kByte).
“File name prefix” Enter a name that will prefix the video recording file name.
(see snapshot section for details)
Log file
Saves the current system log contents in a text file.
Custom Message
A user-defined message in the form of a text file is sent additionally.
13.1.4 Action
You can configure actions here which should be executed when an alarm has been triggered.
“Trigger virtual alarm” An alarm message is sent to virtual output1 or output2 by network command. Make
sure that only output2 is available for schedule EXT. The virtual outputs can only be used with SecvestIP or
IP alarm module.
“Turn on white light LEDs” If the control field is activated, the white light LED on the camera will be turned
on. The lighting period can be set in the seconds field. A maximum of 60 seconds can be entered. You can
select whether the white light LEDs are turned on at any time of day (always) or only at night (night mode).
As the video verification (motion detection) only functions during daylight, the camera switches on the white
light LEDs directly after detection of an object by means of the integrated PIR sensor (sensor selection INT).
“Server” the selected medium is sent on a particular server (e.g. an email is sent with a snapshot).
“Create folders automatically” Folders are automatically created in the directory of the network drives
“Customized folder” The unique name of the folder is determined using variables.
The variables that are available can be found in the table below.
Symbol Example/function
/ Create a new folder
%IP = IP address 192.168.0.1
%N = Event name Motion_W1
%Y = Year 2010
%M = Month 03
%D = Day 04
%H = Hour 14
“Example text” “Example text”
Trigger