Now program the F3 function key on the arming station.
Call up the installer menu.
Under Other Devices, select the Arming station menu point.
Under Edit arming station, select the trained Arming station 1.
The trained arming station is indicated by the symbol.
Now
select the F3 key.
Select the Output number menu point.
Now select the (HW)Output 01
Select the Impulse function (approx. 4 seconds).
Go back to the installer menu and change Output 01 to the user defined setting.
Under Outputs, select the Edit output menu point.
Edit Output 01 and select User Defined as type.
Now go back to the operating mode.
You can now switch output 01 using the F3 function key.
Arming statio n (1) F3
(HW)Output 01
(HW)Output 02
(RF)Output 03
(RF)Output 04
Select Back
INSTALLER MENU
Other Devices
Select Close
OTHER DEVICES
Ext Sirens
Info Module/ Int Sirens
WAM
Arming station
Select Back
Edit arming station
Arming station 1
Arming station 2
Arming station 3
Arming station 4
Select Back
ARMING STATION (E)
Add/Del arming station
Edit arming station
Select Back
Edit arming station
F1 key
F2 key
F3 key
F4 key
Select Back
Arming statio n (1) F3
Full Set
Part Set
Unset
Output number
Select Back
Arming statio n (1) F3
On
Off
Toggle
Impulse
Select Back
INSTALLER MENU
Outputs
Select Close
OUTPUTS
Add output
Edit output
Select Back
(HW)Output 01
Name: Output 01
Type: User Defined
On at: 00 : 00
Off at: 00 : 00
Edit Back
(HW)Output 01
Name: Output 01
Type: Not used
Edit Back
m
m