Installation Manual

18
3.5 Accessing the alarm centre
In order to not trigger an alarm when leaving (Ext Time) or entering (Ent Time) the
area, a delay time must be defined for accessing the centre in Partition 01.
Access the installer menu and set the exit or entry delay under the “Partitions” menu
item.
Select Partions 01.
Select the “Name” menu item, then enter a new name for the partition: Ground floor
Select the type: Time
Set 10 seconds for the exit delay time and 120 seconds for the entry delay time.
In our example, the ground floor (Partition 01) is set as follows: Opening detector
OD13-GF-HA Type: Final Exit
Motion sensor MS4-GF-HA Type: Entry Route
When the house is exited, the system is activated within 10 seconds.
When returning to the house, you have 120 seconds to disable the system.
You must deactivate the system within 120 seconds and may not enter
any other areas where the detectors are not set to Entry Route.
In the installer menu:
Æ
Select the Partitions menu item.
OD13-GF-HA
MS4-GF-HA
Å Exit = 10 seconds
Entrance = 120 seconds Æ
C