AquaSense® Z6913-XL and Z6915-XL Series Sensor-Operated Lavatory Faucets for Battery, Plug-In, or Hardwire Installations, Connected Installation, Operation, Maintenance, and Parts Manual Patented and Patents Pending Z6915-XL Z6913-XL WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov ADVERTENCIA: Cáncer y daño reproductivo - www.P65Warnings.ca.gov AVERTISSEMENT: Cancer et effets néfastes sur la reproduction - www.P65Warnings.ca.
This Page Intentionally Left Blank
Aqua Sense® Faucets Package Contents Z6915-XL-W1 (As Shown) Aerator and Key Spout Assembly (Studs not Shown) Z6913-XL-W1 (As Shown) Aerator and Key Spout Assembly Base Gasket Base Gasket Shank Mounting Kit Shank Mounting Kit Electronics Box with Ceramic Valve Filter Electronics Box with Ceramic Valve Filter DC Adapter Endpoint (-W1 Only) Y-Cable (-W1 Only) CWB FV806 Rev.
Z6915-XL-W2 (As Shown) Z6913-XL-W2 (As Shown) Aerator and Key Spout Assembly (Studs not Shown) Aerator and Key Spout Assembly Base Gasket Batteries Base Gasket Batteries Shank Mounting Kit Shank Mounting Kit Sensor Inline Connector Sensor Inline Connector Hydrogenerator Hydrogenerator Electronics Box with Solenoid Monitor (-W2 Only) Electronics Box with Solenoid Filter Monitor (-W2 Only) Required Tools Adjustable Wrench 3/32” & M3 Hex Key Wrenches (Supplied) Optional Accessories GI MA C
Overview: -W1 & -W2 Only: Zurn connected faucets transmit data 24/7 to the Zurn plumbSMART™* web portal and mobile app. Proactively monitor your faucet activations and water usage, receive real-time alerts for preset high and low usage parameters, and access system data for trends and predictive maintenance anytime and anywhere. All Configurations: AquaSense® sensor faucets are ideal for high-use applications where durability and hands-free operation are necessary.
Important Safety Information (All Configurations): • Installer is responsible for ensuring the product is installed and conforms to all plumbing codes and ordinances. • Do not convert or modify this Zurn product yourself. All warranties will be voided. • Water supply lines must be sized according to building designer in order to provide adequate water supply for each fixture. • Flush all water lines prior to making connections.
Cover Plate Installation Instructions (All Configurations) 1. (For faucets with -CP4 or -CP8 suffix). Pass sensor connector wire and shank through gasket. Align gasket with faucet bottom and press firmly together. Pass sensor connector and shank through cover plate and fasten to the faucet with the provided screws. Spout Installation Instructions (All Configurations) NOTE: Before installation, turn off water supplies to existing faucet and remove faucet if replacing an existing device.
Endpoint & Electronic Module Installation Instructions (-ACA/-CWB) 1. Remove the electronics module from box 3a. Optional ACA version: Connect supplied inline connector and AC adapter. ACA 2. Tighten electronics module assembly to shank and connect water line(s). Connect Sensor. 3b. Optional HW6 (Hardwired 6V) version: Connect supplied inline connector and hardwire adapter.
Optional MJ unit (sold separately) Note: Do not connect more than 3 boxes to a single transformer -MJ -HW6 FAUCET BLACK ( LI NE NE)) VAC IIN N RED (+ (+)) WHITE ( NEUTRA RAL L) FRAME/SAFETY GROUN GROUND D G REEN/YELLOW BLUE ((-)) P6000--HW6 WIRING P6000 BLACK/W /WH HIT ITE E STRIPE (+) 18 AWG (MIN) MAX LENGTH 40’ FAUCET FAUCET Notes: 1. Failure to observe proper polarity will result in failure of the sensor and/or power converter. 2. Use #18 AWG for interconnections. FV806 Rev.
Electronics Module Installation Instructions (-HYD) 1. Connect hydrogenerator(A) downstream of electronics module(B) and filter(C) to bottom of electronics module. 2. Connect sensor inline connector to electronics module and hydrogenerator. A B C 3. Open battery module using supplied Allen wrench and install supplied alkaline batteries in the electronics module. 4. Tighten electronics module assembly with hydrogenerator to shank and connect water line(s).
Endpoint & Electronic Module Installation Instructions (-W1) 1.a. Install endpoint on wall surface within 2 feet radius of faucet with dry wall anchors & screws or doubled sided VHB tape 1.b. For concealed wiring installation, drill 3/16” hole in wall surface for DC power cable , route wire-end through hole to HW6 unit. After routing, apply sealant around wire in hole. 2. Connect endpoint and DC power cable. 4. Connect endpoint and electronics module assembly using supplied Y cable.
5.c. Optional MJ unit (sold separately) Note: Do not connect more than 3 boxes to a single transformer -MJ -HW6 FAUCET BLACK ( LI NE NE)) VAC IIN N RED (+ (+)) WHITE ( NEUTRA RAL L) FRAME/SAFETY GROUN GROUND D G REEN/YELLOW BLUE ((-)) P6000--HW6 WIRING P6000 BLACK/W /WH HIT ITE E STRIPE (+) 18 AWG (MIN) MAX LENGTH 40’ Notes: 1. Failure to observe proper polarity will result in failure of the sensor and/or power converter. 2. Use #18 AWG for interconnections. 6. Connect Y-cable to the spout sensor.
Monitor & Electronic Module Installation Instructions (-W2) 1. Connect hydrogenerator(A) downstream of electronics module(B); connect the electronics module(B) downstream of filter(C). Do not connect the electronic module to spout. 2. Connect sensor inline connector to electronics module and to the hydrogenerator. A B C 4. 3. Install Monitor on wall surface within 2 feet radius of faucet with dry wall anchors & screws or doubled sided VHB tape. Loosen lid screw with supplied 3mm Allen wrench.
7. 8. Ensure that sink is clear of tools/debris and is in normal operating condition. Remove protective film from sensor lens if one is present. 9. Turn on water supply(ies). Tighten electronics module assembly with the hydrogenerator to shank and connect water line(s). 10. Connect sensor cable from spout to monitor. Sensor Range Adjustment (All configurations when necessary) 1. Ensure that the faucet is installed and powered has been applied. 2.
Care and Cleaning Instructions (All Configurations) • Do not use any abrasive or chemical cleaners to clean the faucets. Do not use any cleaners with an acid base. • If abrasives or chemicals are used it can lead to dulling of luster, attacking of chrome plating or decorative finishes. • ONLY use mildly warm soapy water, and then wipe the device dry with a clean/soft towel or cloth.
Adjustable modes and features selection (-W2/-HYD) To adjust features from default configuration, you must remove the battery tray. Once battery tray is removed you will see the switches. Switch Position: Purge (Hours) Disable: 12: 24: 48: 30: 5: 10: 15: 60: Less Time-out Time (Seconds) All switches shown in default mode.
Trouble Shooting: Faucet (Ceramic Valve) Problem Possible Cause Faucet is non-responsive No power. Sensor and electronic connector cable has bent or broken pins. Sensor lens could have surface damage, scratches, or deposit build ups. Micro-processor has locked up. Water does not stop Sensor and electronic connector cable has bent or broken pins. Corrective Action Verify power provided by HW6 or ACA Check to see if pins are missing, bent, or broken.
Trouble Shooting: Faucet (Solenoid Valve) Problem Faucet is non-responsive Possible Cause Corrective Action Battery voltage low. Change out batteries Electronic box connector cable has bent or broken pins. Sensor lens could have surface damage, scratches, or deposit build ups. Sensor lens could be obstructed by environmental factors such as highly reflective surfaces or bright lighting conditions. Check to see if pins are missing, bent, or broken.
Trouble Shooting: LoRa Monitor (-W1/-W2) Problem “Device Not Communicating” posted in plumbSMART Corrective Action Step 1 Verify LoRa Monitor electronics are plugged in / Verify batteries installed in LoRa Monitor electronics and have sufficient charge (whichever applies). Install new batteries, as needed. Alert on product’s page in plumbSMART should clear within 1 hour or on next faucet activation. (Refresh web page by clicking on reload icon in the browser to clear the alert.
Trouble Shooting: Gateway (-W1/-W2) Problem “Status – Good” posted in plumbSMART and faucet actuation event data not appearing in plumbSMART (< 2 hours) or “Device Not Communicating” warning or severe alert posted in plumbSMART for all devices (> 3 hours) Corrective Action Step 1 Verify gateway Status LED flashes twice every 2 seconds. If LED is OFF or ON solid, power cycle the gateway and wait for no more than 5 minutes for unit to initialize and connect.
Filter and Mixing Valve Installation (All Configurations) Control Box Attach adapter or Braided Hose (-SSH) here with -MV and TMV-1 options P6900-120BC, Filter in standard faucet installation P6900-12BC Filter P6900-12BC Filter P6900-MV-ADAP [Supplied Adapter] for -MV & -TMV-1 Options -SSH Option Need to hold at pointed area by suitable wrench or by hand while applying torque to the supply hose nut. Do not over torque the nut.
Accessing the Solenoid (-W2/-HYD) To service solenoid use Phillips head screw driver to remove the screws on both sides of the electronics box. FV806 Rev. C 06/22/22 Page 22 With screws removed, the electronics box can slide off and allow access to the solenoid for service.
Z6913-XL-ACA/CWB & Z6915-XL-ACA/CWB Parts List 1B 1A 11 2A 2B 12 3 13 3 5 6 4 7 4 8 10 9 Description Item 1A: Z6915 Spout Assembly with Sensor Item 1B: Z6913 Spout Assembly with Sensor Item 2A: Z6915 Base Plate Gasket Item 2B: Z6913 Base Plate Gasket Item 3: Mounting Kit Item 4: Ceramic Valve Item 5: Plug-In Power Converter Product No.
Z6913-XL-HYD & Z6915-XL-HYD Parts List 1A 1B 6 2A 13 3 2B 7 3 4 4 5 5 8 14 15 9 10 12 11 Description Item 1A: Z6915 Spout Assembly with Sensor Item 1B: Z6913 Spout Assembly with Sensor Item 2A: Z6915 Base Plate Gasket Item 2B: Z6913 Base Plate Gasket Item 3: Mounting Kit Item 4: Hydrogenerator FV806 Rev. C 06/22/22 Page 24 Product No.
Z6913-XL-W1 & Z6915-XL-W1 Parts List 1B 1A 13 2A 2B 14 15 3 3 5 6 4 4 7 8 9 10 12 11 Description Item 1A: Z6915 Spout Assembly with Sensor Item 1B: Z6913 Spout Assembly with Sensor Item 2A: Z6915 Base Plate Gasket Item 2B: Z6913 Base Plate Gasket Item 3: Mounting Kit Item 4: Ceramic Valve Items 5-8: Smart Connected Faucet Retrofit Kit Product No.
Z6913-XL-W2 & Z6915-XL-W2 Parts List 1B 7 1A 8 2A 2B 16 3 3 6 4 4 5 15 5 13 14 9 10 12 11 Description Item 1A: Z6915 Spout Assembly with Sensor Item 1B: Z6913 Spout Assembly with Sensor Item 2A: Z6915 Base Plate Gasket Item 2B: Z6913 Base Plate Gasket Item 3: Mounting Kit Item 4: Hydrogenerator Assembly Item 5: Electronics Box with Solenoid Item 6: Smart Connected Faucet Retrofit Kit Item 7: 4” Cast Cover Plate w/Gasket Item 8: 8” Cast Cover Plate w/Gasket FV806 Rev.
This Page Intentionally Left Blank
ZURN INDUSTRIES, LLC 511 W. Freshwater Way, Milwaukee, WI U.S.A. 53204 · Ph. 1-855-ONE-ZURN, Fax 919-775-3541 In Canada: ZURN INDUSTRIES LIMITED 7900 Goreway Drive, Unit 10, Brampton, Ontario L6T 5W6, Ph. 905-405-8272, Fax 905-405-1292 Rev. C Date: 06/22/22 C.N. No. 144645 Prod. | Dwg. No. FV806 US 1.855.ONE.ZURN CANADA 1.905.405.8272 ZURN.