Installation Guide

Dimensional Data (inches and [mm]) are Subject to Manufacturing Tolerances and Change Without Notice
SPECIFICATION SHEET
TAG _______
* Regularly furnished unless otherwise specified.
Zurn Industries, LLC | Specification Drainage Operation
1801 Pittsburgh Avenue, Erie, PA U.S.A. 16502 · Ph. 855-663-9876, Fax 814-454-7929
In Canada
| Zurn Industries Limited
7900 Goreway Drive, Unit 10, Brampton, Ontario L6T 5W6, Ph. 877.892.5216
www.zur n.com
OPTIONS (Check/specify appropriate options)
____ Z1201-NL3 3 [76] No-Hub Left Hand Inlet with Flow to Right
____ Z1201-NR3 3 [76] No-Hub Right Hand Inlet with Flow to Left
PREFIXES
____ Z D.C.C.I. System with Zurn ZZ Adjustable Coupling*
____ ZQ D.C.C.I. System with NPT Faceplate, Non-Adjustable Coupling
SUFFIXES
____ -A Auxiliary Support Assembly
(For 'P' Dim. Greater than 18 [457])
____ -CC Corrosion Resistant Cast Iron Coupling
(2-1/4 [57] to 12 [305])
____ -CE EZ-Set™ Coupling (NPSM 6 [152] ,12 [305] or custom)
(NPT 12 [305] or custom)
____ -CL Custom Length Standard Coupling with Integral Test Cap
(Specify Length 4, 8, 10, 12 [102, 203, 254, 305])
____ -CS 2-1/4 [57] Polymer
Coupling with Integral Test Cap
Z1201-N_3
EZCARRY
®
ADJUSTABLE HORIZONTAL HIGH PERFORMANCE
SIPHON JET NO-HUB WATER CLOSET CARRIER SYSTEM
Rev. M
Date: 10/30/2019
C.N. No. 142119
Prod. | Dwg. No. Z1201-N_3
____ -F Floor Mounted, Back Outlet Fixture Support
____ -G Galvanized Cast Iron
____ -M Auxiliary Foot Support
(for 'P' Dim. 7 thru 18 [178 thru 457])
____ -RYK17 One Piece Unistrut Pre-Fab Foot
____ -VP Vandal-Proof Trim
____ -X2 2 [51] Carrier Foot Extension Assembly
____ -X3 3 [76] Carrier Foot Extension Assembly
____ -45 Finishing Frame for Siphon Jet System
____ -50 Flush Valve Supply Support for Water Closets
Product Approx.
Number Wt.
lbs [kg]
Z1201-NL3
Z1201-NR3
55 [25]
Z1201-NR3 Illustrated
ENGINEERING SPECIFICATION: ZURN Z1201-N_3
EZCarry
®
horizontal siphon jet water closet carrier system with high performance waterway and 3" [76mm] no-hub connections.
System includes Dura-Coated cast iron main fitting with hydro-mechanically optimized sweep and extended 2" [51mm] vent,
adjustable gasketed faceplate, floor mounted pre-fab slotted foot supports with top anchoring pre-fab support base, heavy-duty
1/2" [13mm] rear anchor tie down, fixture bolts, trim, stud protectors, bonded “Neo-Seal” gasket, and corrosion resistant,
adjustable 3" [76mm] dia. X 6" [152mm] coupling with integral test cap designed to increase flow velocity and line carry. EZCarry
®
system complies with the requirements of ASME A112.6.1M up to a 500 lbs [227 kg] static load rating.
Note:
1. Z coupling, Min. 'P' Dim.
Obtainable=2 [51].
ZQ coupling, Min. 'P' Dim.
Obtainable=5 [127].
EZ-Set
TM
Coupling, Min. 'P' Dim.
Obtainable=4-1/4 [108] or
2-1/16 [52] for 12 [305] NPT.
2. Feet bolted to floor using min.
1/2 [13] dia. anchors.
3. Rear anchor foot required for
secure installation.
1
4
[6] MIN.
4
1
4
[108] MAX.
4
1
2
[114]
5
1
4
[133]
5
3
4
[146]
2
1
2
[64]
18 [457]
17
1
8
[435]
15
3
8
[391]
1
1
4
[32]
'P' DIM
5
1
4
[133] MIN. 6 [152] MAX.
W/ STANDARD COUPLING
10
3
4
[273]
FINISHED WALL
4
1
2
[114] MIN.
8
5
8
[216] MAX.
12
7
8
[327] MIN.
17 [432] MAX.
9 [229]
9
5
8
[245]
'N' DIM
7
7
16
[189]
'K' DIM
4
5
8
[117]
'A' DIM
Ø3 [76]
NO-HUB
'A' DIM
Ø3 [76]
NO-HUB
5
3
4
[146]
2
3
8
[60]
Ø2 [51] NO-HUB VENT
'B' DIM
11
7
16
[291]
ANCHOR LUG
7
1
2
[191]
2
1
2
[63]