Quick Start Guide

Do not connect a computer or switch directly to the PoE port of the
Router due to high PoE power.
1
PoE
LTE Outdoor Unit
LTE eNB
Firewall
Internet
LTE CPE
MF256 Series
Quick Start Guide
About this document
Panel of device
This manual will serve as a Quick Start Guide to the LTE Device Model
MF256 series. It includes two parts, an indoor unit and an outdoor unit.
In this paper, the indoor unit will be replaced by Router, and the
outdoor unit will be replaced by ODU.
· I/O Panel of Router·
· LED Panel of Router ·
2 3
Make sure you have everything you need to properly configure the
device.
What do you need
4
1. The ODU connects to the LTE network.
2. The ODU is connected to the Router, operated with Router to
provide Internet sevices.
3. The ODU is power supplied by the Router with PoE.
4. The Router functions as a LAN & Wi-Fi gateway.
This quick installation guide shows you how to configure your ODU
and Router in order to access the Internet.
Before you begin, make sure that you are familiar with all accident
prevention and safety procedures necessary for working at height and
with electricity.
DO NOT install the ODU during a lightning storm.
The ODU can be mounted on an antenna pole or mast or on a wall
using the supplied mounting bracket.
Place a CAT5e Ethernet cable from the location of your intended Router
to the desired ODU location.
The maximum distance of the CAT5e cable is limited to 100 meters.
If you use cable extenders to cover a greater distance, signal
attenuation may occur.
If you intend to use cable clamps or other methods to secure the cable,
do not tighten them yet. Leave the cable loose until after you finish
installing the Router and ODU.
To connect the CAT5e Ethernet cable:
Step 1 Open the ODU cover by taking the screws from the housing.
Step 2 Connect the end of the CAT5e Ethernet cable to the PoE port of
the ODU.
Step 3 Place the cover on the ODU housing and turn the screw.
· Choose a mounting point that is sturdy enough to hold the ODU, even
during high winds.
· When choosing a location to install the ODU, remember that the ODU’s
front panel should point towards your service provider’s nearest base
station. You do not need to be able to see the base station from the
ODU’s position. However, if you experience difficulties with signal
reception, a Line of Sight (LoS) connection may produce better results.
· It is suggested that you transport the ODU to its intended installation
location in its original protective packaging.
How does it work
· LAN and WAN ·
Configure hardware
CAUTION
Choose Location
5
Connect the Router to ODU
Computer
Router Adapter
Place a CAT5e Ethernet cable (not included) from the location of your
intended Router to the desired ODU location.
The maximum distance of the CAT5e cable is limited to 100 meters.
If you use cable extenders to cover a greater distance, signal
attenuation may occur.
If you intend to use cable clamps or other methods to secure the cable,
do not tighten them yet. Leave the cable loose until after you finish
installing the Router and ODU.
Connect the Router
6
Step 2 Connect the power adapter to the Router. The POWER LED
turns on a solid green-yellow once connected.
Step 3 Connect the Ethernet cable from the computer to one of the
Router's LAN ports.
CAUTION
NOTE: Make sure you have inserted the SIM card into the ODU.
Step 1 Connect the CAT5e Ethernet cable to the Router WAN/PoE port.
· Hardware connections of Router ·
WAN/PoE
Core Network
Router
ODU Ethernet CABLEPOWER SUPPLY
· I/O panel of ODU ·
ODU
Insert a SIM Card to the Slot
Make sure the ODU is turned off before you insert your SIM card. It is
recommended to NOT connect the PoE cable you do this step.
Otherwise, the SIM card may be damaged.
CAUTION
Step 1 Remove the cover . Step 2 Insert your SIM card.
Step 4 Align and put the cover to
protect it in the ODU.
Step 3 Insert the cable
7
See the installation instructions to mount the ODU correctly.
Pole diameter typeThe mounting pole diameter is from Φ25mm to
Φ45mm; If the pole diameter is less than Φ30mm, you need to add a
C-type ring to make sure the device can be mounted on the pole.
The specific mounting steps are as follows:
1. Using a screwdriver to loosen the metal hose clampsthrough the
terminal equipment mounting hole, the metal hose clamps and the pole
is fixed
Mount the ODU
Pole mounting
Metal hose clamps
pole type mounting A
Router

Summary of content (2 pages)