FCC PART 15 COMPLIANCE Compliance Statement (Part 15.19) WARNING: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference and (2) This device must accept any interference received, including interference that may cause undesired operation. Warning (Part 15.21) Caution: Any change or modification not expressly approved by Zonar Systems could void the user’s authority to operate the equipment.
TABLE OF CONTENTS WHAT IT IS ...............................................................................................................................3 HOW THE SYSTEM WORKS...................................................................................................3 WHY IT MATTERS ...................................................................................................................3 EQUIPMENT DESCRIPTION ...............................................................................
LIMITED WARRANTY Zonar does not represent or warrant that the hardware and software are free of bugs or errors and shall not be liable for any losses (financial or non-financial) occurring as a result of such bugs or errors. No other warranty express or implied, including any warranties of merchantability or particular purpose, is provided for any hardware or software provided pursuant to this contract.
WHAT IT IS The Zonar 2010 Replaces Paper Forms For Safety Inspections The Zonar 2010 replaces all the paperwork that’s required by Federal and State regulations for your pre and post-trip inspections. It’s a handheld reader for radio frequency identification (RFID) tags. The RFID tags have been placed around the vehicle you drive in critical inspection areas or zones. So now as you go around the vehicle checking components, instead of paper forms, you’ll use the Zonar 2010.
EQUIPMENT DESCRIPTION Date/Time; Spotlight Indicator; Battery Level; (Title Line) Instruction Line Info button for main menu LEFT arrow Red N (no) button Power button for turning Zonar 2010 ON/OFF Spotlights 06/15/02 08:30 REPORT HISTORY CURRENT REPORT MANUAL INSP SET CONTRAST VERSION STORE CURR RPT > Cursor character > Display Window UP arrow SELECT ITEM Light (for spotlights) button RIGHT arrow READ/ENTER button DOWN arrow Charging indicator Light Power/Data Connector 4 Green Y (yes) butto
KEYPAD & NAVIGATION USE: TO: Power button • Turn the Zonar 2010 on/off Info button • Return to the main menu at any time (except when you’re being prompted to enter a value or answer a question) READ/ENTER button • Read a card or tag • Enter mileage/hours Light button • Turn the spotlights on/off UP arrow • Scroll up • Add by increments of 1 (e.g.
6
HOW TO USE THE ZONAR 2010 FOR SAFETY INSPECTIONS Complete Pre/Post-trip Inspections • Turn on the Zonar 2010 - Remove the Zonar 2010 from its vehicle mount - Press Power button • Log in - Press READ/ENTER button - Place your Zonar ID Card within 2 inches of the Zonar 2010’s spotlights - Press any button after reviewing System Info screen - Select inspection configuration using the Right button on the desired inspection.
TO: THEN: Add increments of 1 Press the UP arrow Decrease increments of 1 Press the DOWN arrow Add increments of 10 Press the RIGHT arrow Decrease increments of 10 Press the DOWN arrow Record the mileage in the report Press READ/ENTER Note: Holding the arrow buttons accelerates adding or decreasing increments.
- Decide whether the vehicle is safe to operate with the defective condition(s) IF: THEN: The vehicle is safe to operate with the defective condition Press the green Y (yes) button to flag the defect as Yellow The vehicle isn’t safe to operate with the defective condition Press the red N (no) button to flag the defect as Red Note: If you need to enter a component that’s not listed: 1) Scroll to OTHER 2) Press the RIGHT arrow to go to the next screen 3) Use the UP, DOWN, RIGHT, LEFT arrows to select th
• Store the current report IF: AND: THEN: The Store Report screen appears after you’ve inspected all the zones You’re ready to make a permanent record of the inspection report Press the green Y (yes) button The Store Report screen appears after you’ve inspected all the zones You’re not ready to make a permanent record of the inspection report Press the red N (no) button Note: You’ll return to the Zones screen and can make changes The Incomplete Report screen appears after selecting Store Curr Repor
INDEX of FUNCTIONS TO: THEN: Activate the RFID tags so they can be read Position the Zonar 2010’s spotlights within 2 inches of tag; press READ/ENTER Add incremental values of 1 Press the UP arrow Add incremental values of 10 Press the RIGHT arrow Accelerate adding/decreasing values Hold the (UP/RIGHT/DOWN/LEFT) arrow after pressing Answer “No” to questions Press the red N (no) button Answer “Yes” to questions Press the green Y (yes) button Charge the batteries Place the Zonar 2010 into its v
INDEX of FUNCTIONS TO: Enter text for an “OTHER” component or condition that’s not listed Enter a “Red” condition (for components that are BAD) THEN: • Use the UP, DOWN, RIGHT, LEFT arrows to select the character you want (use the “>” character for a space; to erase text use the “<” character) • Press READ/ENTER • Press the Info button when you’ve completed entering text Note: The maximum number of characters you can select is 18.