Instructions for Installation and Use of the C3100/200/400 Control Panel Version: 1.0.1 Date: Oct. 2010 About This Manual This manual is a guide to installation and connection of the C3100/200/400 access control operator panel. For how to use the software of the product, see ZKAccess4.0 User Manual.
Instructions for Installation and Use of the C3100/200/400 Control Panel Contents 1 Important Security Instructions.......................................................................1 1.1 Important Security Instructions.................................................................1 1.2 Installation Cautions.................................................................................2 2 Introduction..................................................................................................
Instructions for Installation and Use of the C3100/200/400 Control Panel 4.4 DIP Switch Setting (485 Address Setting, Factory Setting, and Terminal Resistance Setting).......................................................................................
Instructions for Installation and Use of the C3100/200/400 Control Panel 1 Important Security Instructions 1.1 Important Security Instructions 1. Read, follow and keep instructions: Before operating the equipment, read and follow strictly all security and operation instructions. Please keep the instructions in good condition for future reference. 2. Accessories: Please use the accessories recommended by the manufacturer or delivered with the product.
Instructions for Installation and Use of the C3100/200/400 Control Panel If the equipment cannot work normally even though operated as instructed, please be sure to adjust only the control components specified in the operation instructions. Incorrect adjustment of other control components may cause damage to the equipment, and add to troubleshooting workload of the qualified technicians. 8. The equipment falls down or its performance changes obviously.
Instructions for Installation and Use of the C3100/200/400 Control Panel 2. It is recommended not to plug/unplug connection terminals frequently when the system is energized. Be sure to unplug the connection terminals before starting any relevant welding job. 3. Do not detach or replace any control panel chip without permission, because unprofessional operation may cause damage to the control panel. 4. It is recommended not to connect any other auxiliary devices without permission.
Instructions for Installation and Use of the C3100/200/400 Control Panel 13. To protect the access control system against the selfinduced electromotive force generated by an electronic lock at the instant of switching off/on, it is necessary to connect a diode in parallel (please use the FR107 delivered with the system) with the electronic lock to release the selfinduced electromotive force during onsite connection for application of the access control system. 14.
Instructions for Installation and Use of the C3100/200/400 Control Panel 2 Introduction The access control management system is a new modernized security management system, which is an effective measure for security and protection management. It is mainly used to manage entrances and exits of important places, such as banks, hotels, equipment rooms, offices, smart communities, and factories. 2.1 System Function Parameters Highspeed 32bit 400MHz CPU, 32M RAM, and 256M Flash.
Instructions for Installation and Use of the C3100/200/400 Control Panel Output load: working voltage AC ≤ 30V, rated current ≤ 8A; DC ≤ 36V, rated current ≤ 5A. Ctype electronic lock relay output terminal: 10A contact current, 12V DC, with LED status indications. Output terminal of the auxiliary relay: 2A contact current, 30V DC, with LED status indications. With detachable connection terminals made of alloysteel nonmagnetic flange materials.
Instructions for Installation and Use of the C3100/200/400 Control Panel See the C4 indicators in the following figure: Figure 21 Indicators in the C3400 7
Instructions for Installation and Use of the C3100/200/400 Control Panel 3 Connection and Installation 3.
Instructions for Installation and Use of the C3100/200/400 Control Panel 3.2 Installation of Access Control Operator Panel Wires Figure 31 Access Control Operator Panel Wire Installation Diagram Notes: 1. Before connection, make sure the power supply is disconnected, because connection with power connected will cause severe damage to the equipment. 2.
Instructions for Installation and Use of the C3100/200/400 Control Panel 3.
Instructions for Installation and Use of the C3100/200/400 Control Panel Note: The diagram above takes the C3400 for example. By contrast, only onedoor twoway access is applicable to the C3100 system; only twodoor oneway or twodoor twoway access is applicable to the C3200 system. The access control management system consists of two parts: management workstation (PC) and control operator panel. They communicate via TCP/IP and RS485 networks.
Instructions for Installation and Use of the C3100/200/400 Control Panel 3.
Instructions for Installation and Use of the C3100/200/400 Control Panel C3200 terminal connection diagram 13
Instructions for Installation and Use of the C3100/200/400 Control Panel C3400 terminal connection diagram 14
Instructions for Installation and Use of the C3100/200/400 Control Panel Descriptions of the terminals: 1. The auxiliary input may be connected to infrared body detectors, fire alarms, smoke detectors, etc. 2. The auxiliary output may be connected to alarms, cameras, door bells, etc. 3. All the terminals mentioned above are set through relevant access control software. Please see the respective software instructions for details. Ports on the C3 control operator panel: No.
Instructions for Installation and Use of the C3100/200/400 Control Panel 3.5 Connection with Door Sensors, Exit Switches, and Auxiliary Input Devices Door sensor A door sensor is used to sense the open/closed status of a door. With a door sensor switch, an access control panel can detect illegal opening of a door, and will trigger an output of alarm. Moreover, if a door is not closed within a specified period of time after it is opened, the door control panel will also prompt an alarm.
Instructions for Installation and Use of the C3100/200/400 Control Panel Figure 33 Connections between C3400 and Door Sensors, Exit Switches, and Auxiliary Input Devices 17
Instructions for Installation and Use of the C3100/200/400 Control Panel Note: The diagram above takes C3400 for example. By contrast, C3100 provides no auxiliary input interface; C3200 provides two, and C3400 provides four. 3.6 Connection with Wiegand Readers C3100 can connect two Wiegand readers in the onedoor twoway mode. C3200 provides four readers, which can be connected in the twodoor twoway mode.
Instructions for Installation and Use of the C3100/200/400 Control Panel Figure 34 Connection between C3400 and Readers 19
Instructions for Installation and Use of the C3100/200/400 Control Panel 3.7 Relay Output Connection C3100 has two relays (one used as a control lock by default, and the other used as an auxiliary output); C3200 has four relays (two used as control locks by default, and the other two used as auxiliary outputs); C3400 has eight relays (four used as control locks by default, and the other four used as auxiliary outputs).
Instructions for Installation and Use of the C3100/200/400 Control Panel 3. To protect the access control system against the selfinduced electromotive force generated by an electronic lock at the instant of switching off/on, it is necessary to connect a diode in parallel (please use the FR107 delivered with the system) with the electronic lock to release the selfinduced electromotive force during onsite connection for application of the access control system. 1.
Instructions for Installation and Use of the C3100/200/400 Control Panel 3. Dry mode:External power supply for NO Lock 4.
Instructions for Installation and Use of the C3100/200/400 Control Panel 5. Dry mode:The system control the Normally Open lock use the switch value. 6. Dry mode:The system control the Normally Close lock use the switch value.
Instructions for Installation and Use of the C3100/200/400 Control Panel 24
Instructions for Installation and Use of the C3100/200/400 Control Panel 220V AC 3.
Instructions for Installation and Use of the C3100/200/400 Control Panel An access control operator panel is powered by +12V DC. Generally, to reduce power interference between control panels, each control operator panel should be powered separately. When high reliability is required, control panels and electronic locks should be powered respectively.
Instructions for Installation and Use of the C3100/200/400 Control Panel 4 Access Control Operator Panel System Networking 4.1 Access Control Networking Wires and Wiring 1. RS485 communication wires are made of internationally accepted shielded twisted pairs, which prove effective to prevent and shield interference. 2. The power supply is 12V DC converted from 220V. 3. The Wiegand readers use 6core communication shielded wires (RVVP 6×0.
Instructions for Installation and Use of the C3100/200/400 Control Panel distribution). Metal hoses are applicable to ceiling wiring, but must be secure and goodlooking. Shielding measures and shielding connection: If the electromagnetic interference in the wring environment is found strong in the survey before construction, it is necessary to consider shielding protection for data cables when designing a construction scheme.
Instructions for Installation and Use of the C3100/200/400 Control Panel 4.2 TCP/IP Network Communication The Ethernet 10/100BaseT Crossover Cable, a type of crossover network cable, is mainly used for cascade hubs and switches, or used to connect two Ethernet endpoints directly (without a hub). Both 10BaseT and 100BaseT are supported. Printer Management host Card issuer Hub TCP/IP Ethernet C3 control panel C3 control panel C3 control panel Figure 41 TCP/IP Communication System Networking 4.
Instructions for Installation and Use of the C3100/200/400 Control Panel 2. A single 485 bus can be connected with 63 access control operator panels at most, but preferably should be connected with less than 32. 3. To eliminate signal attenuation in communication cables and suppress interference, if the bus is longer than 300 meters, one 120ohm resistance is usually inserted between the first and last access control operator panels on the RS485 bus. 4.
Instructions for Installation and Use of the C3100/200/400 Control Panel 4.4 DIP Switch Setting (485 Address Setting, Factory Setting, and Terminal Resistance Setting) 485 address setting Places 16 of the DIP switch are reserved to set device number for RS485 communication. The code is binary, and the lower places are in the front. When the switch is set to the ON position, it indicates 1 (on); when the switch is set downwards, it indicates 0 (off).
Instructions for Installation and Use of the C3100/200/400 Control Panel Switch Setting Place Address 1 2 3 4 5 6 13 ON OFF ON ON OFF OFF 14 OFF ON ON ON OFF OFF 15 ON ON ON ON OFF OFF 16 OFF OFF OFF OFF ON OFF 17 ON OFF OFF OFF ON OFF 18 OFF ON OFF OFF ON OFF 19 ON ON OFF OFF ON OFF 20 OFF OFF ON OFF ON OFF 21 ON OFF ON OFF ON OFF 22 OFF ON ON OFF ON OFF 23 ON ON ON OFF ON OFF 24 OFF OFF OFF ON ON OFF 25 ON OFF
Instructions for Installation and Use of the C3100/200/400 Control Panel Switch Setting Place Address 1 2 3 4 5 6 40 OFF OFF OFF ON OFF ON 41 ON OFF OFF ON OFF ON 42 OFF ON OFF ON OFF ON 43 ON ON OFF ON OFF ON 44 OFF OFF ON ON OFF ON 45 ON OFF ON ON OFF ON 46 OFF ON ON ON OFF ON 47 ON ON ON ON OFF ON 48 OFF OFF OFF OFF ON ON 49 ON OFF OFF OFF ON ON 50 OFF ON OFF OFF ON ON 51 ON ON OFF OFF ON ON 52 OFF OFF ON OFF
Instructions for Installation and Use of the C3100/200/400 Control Panel upwards and downwards for three times within 10 seconds and finally returned to the OFF position, the factory settings will be restored after the access control operator panel is restarted. Terminal resistance setting Place 8 is for setting the RS485 termination resistance. Putting the switch to the ON position is equivalent to parallel connection of a 120ohm termination resistance between 485+ and 485.