USER MANUAL AL40 Series Version: 1.
Table of Contents Read Before Use......................................................................................................... 1 Safety Precautions....................................................................................................................1 Structure ........................................................................................................................................2 Basic Function ........................................................................
Lockout mode ............................................................................................................................6 9V External Battery ..................................................................................................................7 Emergency Mechanical Key ..............................................................................................8 How to Use .........................................................................................................
Read Before Use Safety Precautions 1. Factory settings of all new locks allow any verification to unlock them. 2. One administrator must be registered on newly installed locks. Ordinary users cannot be registered until an administrator is registered. 3. The lock is equipped with a mechanical key. Store the mechanical key in a safe place. 4. Four alkaline AA batteries (not included) are required to power on the lock, Non-alkaline and rechargeable batteries ARE NOT RECOMMENDED. 5.
Structure 1 7 2 4 5 3 8 6 1. Fingerprint Sensor 5. Lockout Indicator 2. Touchscreen & Detection Area 6. Lockout Knob 3. Keyhole 7. Battery Cover 4. Reset Button 8.
Basic Function User Introduction Group Verification Mode Card Administrator Function Register / Delete User, Password Fingerprint Open The Door, Access the menu Card User Capacity Max.100 Max.100 Max.100 Max.100 Password Open the door Fingerprint Max.100 Max.100 Note: 1. The lock's maximum card/password user capacity is 100. 2. Use a password of six digits.
Initialization Initializing the lock means all data will be deleted and restored to factory default settings. Operation steps: Press and hold the reset button on the body of the lock then remove the battery and put it back again, wait for 3 seconds, the lock will prompt “Restore to default settings, wait a moment.” The initialization is finished when the lock prompts “completed”.
Voice Guide The lock provides voice prompts when operating the menu for easy configuration. Volume Setting The lock volume can be set, which has three modes, high volume mode, low volume mode and silent mode. Language Setting* It supports English, Spanish and Portuguese. Every single lock will standard with one language, if you want the language combination, please contact to our sales team.
Add Remote Key* The door can be unlocked by remote control. This is an optional function. Please refer to page 18. Always Open Mode Always Open mode is to keep door always unlocked, allowing people to pass in and out freely. Low Battery Warning "Low battery, replace the batteries" will prompt when the lock battery has low energy. Note: Menu options cannot be accessed in low battery status. Lockout mode Lockout mode indicated that only administrator can unlock the door.
9V External Battery 9V external battery is used to keep the lock operative when its battery is fully discharged. Note: The above battery must be 9V alkaline battery (6LR61).
Emergency Mechanical Key The mechanical key is used to open the door in an emergency. Note: Keep the mechanical key in a safe place.
How to Use Register First Administrator Operating Steps Touch the keypad to wake up the lock Press 0 and # to access the menu Enter three-digit user number Enter fingerprint, card or password Press * to complete Press # to continue registering another user P a g e |9
Note: 1. Verify cards by swiping them over the detection area. 2. Password length must be six digits. 3. Default user number length is three digits, but one or two digit user numbers are accepted by pressing the # key. 4. Press * to cancel registration before the registration is complete.
Register another Administrator Operating Steps Touch the keypad to wake up the lock Press 0 and # to access the menu Verify administrator using fingerprint, card or password Press 1 to register admin, and press # to continue Enter three-digit user number Enter fingerprint, card or password Enter * to complete Enter # to continue registering another admin Note: If you verify administrator by password, then press # after entering the password.
Register User Operating Steps Touch the keypad to wake up the lock Press 0 and # to access the menu Verify administrator using fingerprint, card or password Press 2 to register user, and press # to continue Enter fingerprint, card or password Enter * to complete Enter # to continue registering another user Note: If you verify administrator by password, then press # after entering the password.
Delete Administrator Operating Steps Touch the keypad to wake up the lock Press 0 and # to access the menu Verify administrator using fingerprint, card or password Press 3 to delete admin, and press # to continue Enter three-digit user number Enter * to complete Enter # to continue deleting another administrator Note: If you verify administrator by password, then press # after entering the password.
Delete User Operating Steps Touch the keypad to wake up the lock Press 0 and # to access the menu Verify administrator using fingerprint, card or password Press 4 to delete user, and press # to continue Enter three-digit user number Enter * to complete Enter # to continue deleting another user Note: If you verify administrator by password, then press # after entering the password.
Enroll Additional Credential Operating Steps Touch the keypad to wake up the lock Press 0 and # to access the menu Verify administrator using fingerprint, card or password Press 5 to enroll additional, and press # to continue Enter three-digit user number Enter fingerprint, card or password Enter * to complete Enter # to continue enrolling additional credentials Note: If you verify administrator by password, then press # after entering the password.
Volume Setting Operating Steps Touch the keypad to wake up the lock Press 0 and # to access the menu Verify administrator using fingerprint, card or password Press 6 to set volume, and press # to continue 1. High volume 2. Low volume 3. Silent mode Enter # to confirm Note: If you verify administrator by password, then press # after entering the password.
Setting Operating Steps Touch the keypad to wake up the lock Press 0 and # to access the menu Verify administrator using fingerprint, card or password Press 7 and # to enter the secondary menu Press 1 and # to set Auto Relock mode 1.Enable 2.Disable *Press 2 and # to link to interweb, please refer to the AL30B&AL40B-Zigbee User manual *Press 3 and # to set up language 1.English 2.Spanish 3.Portuguese Enter # to confirm Note: 1.
Always Open Mode Operating Steps Touch the keypad to wake up the lock Press 0 and # to access the menu Verify administrator using fingerprint, card or password Press 8 to set Always open mode, and press # to continue 1. Enable 2. Disable Enter # to confirm Note: If you verify administrator by password, then press # after entering the password.
Add Remote Key* Operating Steps Press 0 and # to access the menu Verify administrator using fingerprint, card or password Press 9 and # to confirm Press 1 and # to add remote key Press unlock button on the remote device Press 2 and # to delete one remote key Press lock button on the remote device Press 3 and # to delete all remote keys Enter # to confirm Note: If you verify administrator by password, then press # after entering the password.
FCC Note This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
equipment Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. The device has been evaluated to meet FCC general RF exposure requirement. The device can be used in portable exposure condition without restriction.
CE Note Manufacturer: ZKTECO CO., LTD. Address: No.26, Pingshan 188 Industry zone, Tangxia Town, Dongguan City, Guangdong Province, China Hereby, ZKTECO CO., LTD.
ZK Building, Wuhe Road, Gangtou, Bantian, Buji Town, Longgang District, Shenzhen China 518129 Tel: +86 755-89602345 Fax: +86 755-89602394 www.zkteco.com © Copyright 2018. ZKTeco Inc. ZKTeco Logo is a registered trademark of ZKTeco or a related company. All other product and company names mentioned are used for identification purposes only and may be the trademarks of their respective owners. All specifications are subject to change without notice. All rights reserved.