Product Name and Model Number User Manual User Manual MB10-VL Date: April 2021 Doc Version: 1.2 English Thank you for choosing our product. Please read the instructions carefully before operation. Follow these instructions to ensure that the product is functioning properly. The images shown in this manual are for illustrative purposes only. For further details, please visit our Company’s website www.zkteco.com. P a g e |1 Copyright©2020 ZKTECO CO., LTD. All rights reserved.
MB10-VL User Manual Copyright © 2021 ZKTECO CO., LTD. All rights reserved. Without the prior written consent of ZKTeco, no portion of this manual can be copied or forwarded in any way or form. All parts of this manual belong to ZKTeco and its subsidiaries (hereinafter the "Company" or "ZKTeco"). Trademark is a registered trademark of ZKTeco. Other trademarks involved in this manual are owned by their respective owners.
MB10-VL User Manual improvement /better operations of the machine/unit/equipment and such amendments shall not give any right to claim any compensation or damages under any circumstances.
MB10-VL User Manual About the Company ZKTeco is one of the world’s largest manufacturer of RFID and Biometric (Fingerprint, Facial, Finger-vein) readers. Product offerings include Access Control readers and panels, Near & Far-range Facial Recognition Cameras, Elevator/floor access controllers, Turnstiles, License Plate Recognition (LPR) gate controllers and Consumer products including battery-operated fingerprint and face-reader Door Locks.
MB10-VL User Manual Document Conventions Conventions used in this manual are listed below: GUI Conventions For Software Convention Bold font > Description Used to identify software interface names e.g. OK, Confirm, Cancel Multi-level menus are separated by these brackets. For example, File > Create > Folder. For Device Convention Description <> Button or key names for devices. For example, press [] Window names, menu items, data table, and field names are inside square brackets.
MB10-VL User Manual Table of Contents SAFETY MEASURES ..................................................................................................................................... 7 1 INSTRUCTION FOR USE ....................................................................................................................... 10 FINGER POSITIONING ............................................................................................................................................................
MB10-VL User Manual 9 DEPARTMENT MANAGEMENT ............................................................................................................ 50 ADD A DEPARTMENT ....................................................................................................................................................................50 EDIT A DEPARTMENT ........................................................................................................................................................
MB10-VL User Manual Safety Measures The below instructions intend to ensure that the user can use the product correctly to avoid danger or property loss. The following precautions are to keep users safe and prevent any damage. Please read carefully before installation. Noncompliance with instructions could lead to product damage or physical injury (may even cause death). 1.
MB10-VL User Manual Electrical Safety • Before connecting an external cable to the device, complete grounding properly, and set up surge protection; otherwise, static electricity will damage the mainboard. • Make sure that the power has been disconnected before you wire, install, or dismantle the device. • Ensure that the signal connected to the device is a weak-current (switch) signal; otherwise, components of the device will get damaged.
MB10-VL User Manual Note • Make sure whether the positive polarity and negative polarity of the DC 12V power supply is connected correctly. A reverse connection may damage the device. It is not advisable to connect the AC 24V power supply to the DC 12V input port. • Make sure to connect the wires following the positive polarity and negative polarity shown on the device's nameplate.
MB10-VL 1 User Manual Instruction for Use Finger Positioning Index, middle, or ring finger are the recommended fingers to use, and avoid using thumb or pinkie as they are difficult to position correctly on the fingerprint reader and get suitable output. Too low Too close to the edge Vertical Note: the recommended method when pressing your fingers onto the fingerprint reader for registration and identification.
MB10-VL Facial expression Standing posture User Manual Note: During enrolment and verification, please remain natural facial expression and standing posture. P a g e | 11 Copyright©2021 ZKTECO CO., LTD. All rights reserved.
MB10-VL User Manual Face Registration Try to keep the face in the centre of the screen during registration. Please face the camera and stay still during face registration. The screen looks like the image below: Correct face registration and authentication method Cautions for registering a face When registering a face, maintain a 40cm to 80cm space between the device and the face. Be careful not to change the facial expression. (smiling face, drawn face, wink, etc.
MB10-VL User Manual Verification Mode 1.4.1 Fingerprint Verification 1: N fingerprint verification mode It compares the current fingerprint with all the fingerprint data that is available in the device. The device enters the fingerprint authentication mode when a user presses his/her finger onto the fingerprint scanner. Please follow the recommended way to place your finger onto the sensor. For details, please refer to 1.1 Finger Positioning.
MB10-VL User Manual Enter the User ID on the main screen to enter 1:1 fingerprint verification mode. 1. Enter the user ID and press [M/OK]. If the user has registered a face, a password and card in addition to his/her fingerprints and the verification method is set to password/ fingerprint/ card/ face verification, the following screen will appear. Select the fingerprint icon to enter fingerprint verification mode: 2. Press the fingerprint to verify.
MB10-VL User Manual 1.4.2 Facial Verification 1:N Facial Verification It compares the current acquired facial images with all the face data registered in the device. The following is the pop-up prompt box of comparison result. 1:1 Facial Verification It compares the face captured by the camera with the facial template related to the entered user ID. For 1:1 facial verification, enter the User ID on the main interface and enter the 1:1 facial verification mode. Enter the user ID and press [M/OK].
MB10-VL User Manual After successful verification, the following display screen appears. If the verification fails, it prompts “Please adjust your position!”. 1.4.3 Password Verification It compares the entered password with the registered User ID and password. Enter the User ID on the main screen to enter the 1:1 password verification mode. 1. Enter the user ID and press [M/OK]. If an employee has registered fingerprint and face in addition to password, the following screen will appear.
MB10-VL User Manual 2. Input the password and press [M/OK]. The following screen displays on successful and failed verification respectively. On successful verification On failed verification 1.4.4 Card Verification Only the product with the card module offers the card verification function. 1:N Card Verification It compares the card number in the card induction area with all the card number data that is available in the device.
MB10-VL On successful verification User Manual On failed verification 1:1 Card Verification It compares the card number in the card induction area with the number associated with the employee's User ID registered in the device. Users can try verifying their identity with 1:1 verification mode if they are unable to get access with the 1:N authentication method. Enter the User ID on the main screen to enter 1:1 card verification mode. 1. Enter the user ID and press [M/OK].
MB10-VL User Manual 2. Place the card in the card induction area to verify. After successful verification, the following display screen appears. 1.4.5 Combined Verification For enhanced security, this device offers the option of using multiple forms of verification methods, as shown in the picture below. Note: 1) "/" means “or”, and "+" means “and”. 2) You must register the required verification information before using the combination verification mode, otherwise the verification may fail.
MB10-VL 2 User Manual Main Menu Click [M/OK] on the initial interface to enter the main menu, as shown below: Items Descriptions User Mgt. To add, edit, view, and delete basic information of a user. User Role To set the permission scope of the custom role and enroller, that is, the rights to operate the system. COMM. To set the relevant parameters of Ethernet, PC connection, wireless network, cloud server setting and network diagnosis.
MB10-VL User Manual Access Control To set the parameters of the lock and the relevant access control device. USB Manager To transfer data such as user data and attendance logs from the USB disk to the supporting software or other devices. Attendance Search Query the specified access record, check attendance photos, and blacklist photos. Auto test To automatically test whether each module functions properly, including the screen, audio, camera, and real-time clock.
MB10-VL 3 User Manual User Management Adding Users Select User Mgt. on the main menu and select New User. Register a User ID and Name Enter the User ID and Name by selecting the respective options. Note: 1) A username can contain a maximum of 17 characters. 2) The user ID may contain 1-9 digits by default. 3) You can modify your ID only during the initial registration and can't be modified later. 4) The User ID cannot be duplicated.
MB10-VL User Manual Setting the User Role There are two types of user accounts: Normal Users and Super Admin. If there is already a registered administrator, the normal users have no rights to manage the system and may only access authentication verifications. The administrator owns all management privileges. If a custom role is set, you can also select custom role permissions for the user. Select User Role to set Normal User or Super Admin.
MB10-VL User Manual Register fingerprint Select Fingerprint to enter the enroll fingerprint page. Users can choose one or more fingerprint(s) to enroll. Press the finger horizontally onto the fingerprint sensor. The registration interface is shown below: Register Face Select Face on the Verification mode to enter the face registration page. Users need to face the camera such that their whole face is visible on the device's screen and all the important features of the face are visible.
MB10-VL User Manual Register Card Select Card on the Verification mode page to enter the card registration page. On the Card interface, swipe the card underneath the card reading area. The card registration will be successful. If the card is registered already then, the “Duplicate Card” message shows up. The registration interface is as follows: Register password Select Password on the Verification mode page to enter the password registration page. Enter a password and re-enter it. Select M/OK.
MB10-VL User Manual Note: The password may contain one to eight digits by default. Register user photo When a user registered with a photo passes the authentication, the registered photo will be displayed. Select User Photo, Select M/OK to take a photo. Then Select ESC to exit and return to the New User interface. Note: While registering a face, the system will automatically capture a picture as the user photo.
MB10-VL User Manual Edit Users Choose a user from the list and select Edit to enter the Edit user interface: Note: The operation of editing a user is the same as that of adding a user, except that the user ID cannot be modified when editing a user’s detail. Deleting Users Choose a user from the list and select Delete to enter its interface. Select the user information to be deleted and click M/OK. Note: If you select Delete User, all information of the user will be deleted.
MB10-VL 4 User Manual User Role If you need to assign any specific permissions to certain users, you may edit the “User Defined Role” under the User Role menu. You may set the permission scope of the custom role (up to 3 roles) and enroller. Select User Role on the main menu interface. 1. Select an item to set a defined role. Select the Enable Defined Role option to enable this defined role. Select Name and enter the name of the role. P a g e | 28 Copyright©2021 ZKTECO CO., LTD. All rights reserved.
MB10-VL 2. User Manual Select Define User Role to assign the privileges to the role. Click ESC to save and return after the privilege assignment is complete. Note: You need to select the features in sub-menus. If the device has a role enabled, you may assign the roles you set to users by selecting User Mgt. > New User > User Role. If no super administrator is registered, the device will prompt "Please register super administrator user first!” after selecting the enable bar.
MB10-VL 5 User Manual Communication Settings Select COMM. on the main menu to get into communication settings and set parameters of the network, PC connection, WIFI, and cloud server. Network Settings When the device needs to communicate with a PC over the Ethernet, you need to configure network settings and ensure that the device and the PC are connecting to the same network segment. Select Ethernet on the Comm. Settings interface. P a g e | 30 Copyright©2021 ZKTECO CO., LTD. All rights reserved.
MB10-VL User Manual Item Descriptions IP Address The factory default value is 192.168.1.201. Please set them according to the actual network situation. Subnet Mask The factory default value is 255.255.255.0. Please set them according to the actual network situation. DNS The factory default address is 0.0.0.0. Please set them according to the actual network situation. TCP COMM. Port The factory default value is 4370. Please set them according to the actual network situation.
MB10-VL User Manual Wireless Network The device provides a Wi-Fi module, which can be built-in within the device module or can be externally connected. The Wi-Fi module enables data transmission via Wi-Fi (Wireless Fidelity) and establishes a wireless network environment. Wi-Fi is enabled by default in the device. If you don't need to use the Wi-Fi network, you can toggle the Wi-Fi to disable the button. Select Wireless Network on the Comm. settings interface to configure the Wi-Fi settings.
MB10-VL User Manual Select Add WIFI Network to add the WIFI manually and press [M/OK]. On this interface, enter the WIFI network parameters (the added network must exist.) Note: After successfully adding the WIFI manually, follow the same process to search for the added WIFI name. Advanced Setting On the Wireless Network interface, select Advanced to set the relevant parameters as required.
MB10-VL User Manual IP Address The IP address for the WIFI network, the default is 0.0.0.0. It can be modified according to the network availability. Subnet Mask The default Subnet Mask of the WIFI network is 255.255.255.0. It can be modified according to the network availability. Gateway The default Gateway address is 0.0.0.0. It can be modified according to the network availability.
MB10-VL User Manual Network Diagnosis It helps to set the network diagnosis parameters. Select Network Diagnosis on the Comm. settings interface. Enter the IP address that needs to be diagnosed and click Start the diagnostic test to check whether the network can connect to the device. P a g e | 35 Copyright©2021 ZKTECO CO., LTD. All rights reserved.
MB10-VL 6 User Manual System Settings It helps to set related system parameters to optimize the performance and usability of the device. Select System on the main menu interface. Date and Time Select Date Time on the System Setting interface. Item Descriptions Manual Date and Time Can set date and time manually and click [M/OK] to save. 24-Hour Time The device displays 24-Hour time format, when enabled. Date Format Select the date format. P a g e | 36 Copyright©2021 ZKTECO CO., LTD.
MB10-VL User Manual Note: When restoring the factory settings, the time (24-hour) and the date format (YYYY-MM-DD) can be restored to default, but the device date and time cannot be restored. For example, the user sets the time of the device (18:35 on March 15, 2019) to 18:30 on January 1, 2020. After restoring the factory settings, the time of the device will remain 18:30 on January 1, 2020. Attendance Setting Select Attendance on the System interface to alter the attendance rules as required.
MB10-VL User Manual Face Parameters Select Face option on the System interface. FRR Item 1:N Threshold Value 1:1 Threshold Value Face Enrollment Threshold Face Pitch Angle P a g e | 38 FAR Recommended matching thresholds 1:N 1:1 High Low 48 42 Medium Medium 46 40 Low High 43 38 Description Under 1:N verification mode, the verification will only be successful when the similarity between the acquired facial image and all registered facial templates is greater than the set value.
MB10-VL Face Rotation Angle Image Quality User Manual It is the rotation angle tolerance of a face for facial template registration and comparison. If a face’s rotation angle exceeds this set value, it will be filtered by the algorithm, i.e., ignored by the terminal and, no registration and comparison interface will be triggered. It sets the image quality for facial registration and comparison. The higher the value, the clearer the image required. It is required for facial registration and comparison.
MB10-VL User Manual Fingerprint Parameters Select Fingerprint option on the System interface. FRR FAR Recommended matching thresholds 1:N 1:1 High Low 45 25 Medium Medium 35 15 Low High 25 10 Item Descriptions 1:1 Threshold Value Under 1:1 verification method, the verification will only be successful when the similarity between the acquired fingerprint data and the fingerprint template associated with the entered user ID enrolled in the device is greater than the set threshold value.
MB10-VL User Manual Factory Reset Restore the device settings to their factory state, such as communication settings, system settings, etc. (Do not clear registered user data). Select the Reset option on the System interface. Select OK to reset. USB Upgrade Insert the U disk with upgrade file into the device’s USB port, and in the initial interface, press [M/OK] > System > USB Upgrade to complete firmware upgrade operation. Select USB Upgrade option on the System interface.
MB10-VL 7 User Manual Personalize Settings You may customize interface settings under this option. Select Personalize option on the main menu interface. Interface Settings You can customize the display style of the main interface. Select User Interface option on the Personalize interface. Item Description Wallpaper To select the main screen wallpaper according to your personal preference. Language To select the language of the device. P a g e | 42 Copyright©2021 ZKTECO CO., LTD.
MB10-VL User Manual Menu Screen Timeout (s) When there is no operation on the device, and the time exceeds the set value, then the device will automatically go back to the initial interface. You can disable the function or set the value between 60 and 99999 seconds. Idle Time To Slide Show (s) When there is no operation on the device, and the time exceeds the set value, a slide show starts to play. It can be disabled, or you may set the value between 3 and 999 seconds.
MB10-VL User Manual Bell Schedules Settings Many companies choose to use the bell to signify on-duty and off-duty time. When reaching the scheduled time for the bell, the device plays the selected ringtone automatically until the ringing duration passes. Select Bell Schedules option on the Personalize interface. Add a Bell Select New Bell Schedules option on the Bell Schedules interface. Press [M/OK] Bell Status to enable the bell status. 1.
MB10-VL User Manual Edit Bell On the All Bell Schedules interface, select the bell item to be edited. Select Edit to edit the bell schedule time. The editing method is the same as that of a new bell. Delete a Bell On the All Bell Schedules interface, select a bell item to be deleted. Select Delete and select [Yes] to delete the bell schedule. P a g e | 45 Copyright©2021 ZKTECO CO., LTD. All rights reserved.
MB10-VL User Manual Punch States Options Select Punch State Options on the Personalize interface. Item Description Select a punch state mode under this menu option. The options are: Off: Select this to keep the punch state key function disabled. The punch state key set under the Shortcut Key Mappings menu becomes invalid. Manual Mode: Select to switch the punch state key manually, and the punch state key disappears after Punch State Timeout.
MB10-VL User Manual Shortcut Keys Mappings Shortcut keys can be defined as punch state keys or menu function key. When the device is on the main interface, pressing the set shortcut key will display the attendance state or enter the menu operation interface. Select the Shortcut Key Mappings option on the Personalize interface. To set Auto-Switching Time: Choose any shortcut key and select Punch State Options in Function to set the auto-switching time.
MB10-VL 8 User Manual Data Management It helps to delete the relevant data in the device. Select Data Mgt. option on the main menu interface. Delete Data Select Delete Data option on the Data Mgt. interface. P a g e | 48 Copyright©2021 ZKTECO CO., LTD. All rights reserved.
MB10-VL User Manual Item Description Delete Attendance Data To delete all attendance data in the device. Delete All Data To delete information and access records of all registered users. Delete Admin Role To remove administrator privileges. Delete Wallpaper To delete all wallpapers in the device. Delete Screen Savers To delete the screen savers in the device. Note: When deleting the access records, attendance photos, or blacklisted photos, you may select Delete All or Delete by Time Range.
MB10-VL 9 User Manual Department Management Establishing an organizational structure of the company and arranging departments shift is necessary to view the department information of the device. In this menu option, you can add, edit, or remove a department. Select Department on the main menu interface. Add a Department 1. Select Add Dept. and press [M/OK] to enter. P a g e | 50 Copyright©2021 ZKTECO CO., LTD. All rights reserved.
MB10-VL User Manual 2. Select Dept. Name and enter the department name using the T9 input method. 3. Select the Dept. Shifting of the department. Note: 1. The equipment will automatically assign numbers to departments, starting from 1 and so on. 2. Dept. Shift: Select the shift attendance used by all users of the department. Shifts can be set in Shift set > Shifts setting, with a maximum of 24 shifts set by default. Refer to Shift Set section. P a g e | 51 Copyright©2021 ZKTECO CO., LTD.
MB10-VL User Manual Edit a Department There are 8 departments in the device by default. You can edit the department name and department shift, but you cannot delete them. In addition to the 8 default departments, additional departments can be edited and deleted. 1. Select Dept. Lists and press [M/OK] to enter. 2. Select a department to edit and press [M/OK] to enter. 3. Modify Dept. Name and Dept. Shifting and press [M/OK] to save. The editing of the department is the same as of Add Dept.
MB10-VL User Manual Delete a Department It helps to remove one or more department as required. 1. Select Dept. Lists and press [M/OK] to enter. 2. Select a department to delete and press [M/OK] to enter. 3. Select Delete and press [M/OK]. Note: Only departments other than the 8 default departments in the device can be deleted. P a g e | 53 Copyright©2021 ZKTECO CO., LTD. All rights reserved.
MB10-VL User Manual 10 Shift Set Set attendance rules, number of shifts to be used, and schedule employees. Select Shift Set option on the main menu interface. Attendance Rule All attendance statistics are conducted according to the attendance rules. Therefore, the staff attendance rules need to be set first, including late, early leave calculation method, and scheduling type.
MB10-VL User Manual Item Descriptions Count Late On-duty Set a time after which the lateness calculation for an employee should start. If it is disabled, the lateness calculation starts with the start of working hours. Count Leave Off-duty Set a time before which the early leave calculation for an employee should start. If disabled, it is calculated with respect to the end of the working hours. The device supports both department and individual-based scheduling.
MB10-VL User Manual Use the T9 input method to enter "Shift Name” and set the required start and end times. Note: The device supports a maximum of 24 shifts including two default shifts (Shift 1 and Shift 2). All the shifts are editable, and a single shift includes three-time ranges at most. Schedule The shifts should be set based on the actual condition of a company. If no shift is set, the system makes attendance calculations based on default shifts set in attendance rules.
MB10-VL User Manual Department-based Scheduling Select Shift Set > Attendance Rule > Schedule Type > Dept. Shifting to schedule shift for a department. When a shift is selected for a department, it is implemented for all the members of the department. Individual-based Scheduling Select Shift Set > Attendance Rule > Schedule Type > Personal Shift to schedule shift for an individual. 1. Add Schedule 1) Press [M/OK] to enter Schedule interface and select Add Personal Shift. 2) Enter an ID.
MB10-VL 2. User Manual Edit Schedule Enter the Personal Shift Lists for editing when the scheduling of individual employee needs to be adjusted. 1) Select Personal Shift Lists on the Personal Shift interface. 2) Select a scheduled user and press [M/OK]. 3) Select Edit, press [M/OK] to enter and modify the "Shift Name" of the user. Note: The User ID cannot be modified. The other operations are the same as those performed to add a shift. P a g e | 58 Copyright©2021 ZKTECO CO., LTD.
MB10-VL 3. User Manual Delete a shift Go to the Personal Shift Lists, to delete an employee's schedule that is no longer required. 1) Select Personal Shift Lists on the Personal Shift interface. 2) Select a scheduled user and press [M/OK]. 3) Select Delete, press [M/OK], and choose “OK” to delete the Shift successfully. P a g e | 59 Copyright©2021 ZKTECO CO., LTD. All rights reserved.
MB10-VL User Manual 11 Report This menu item allows you to download statistical reports of attendance or attendance setting reports to a USB flash drive or SD card. You can also upload attendance setting reports with defined shifts and employees' schedules. The device gives priority to the schedules in an attendance setting report. Select Report on the main menu interface.
MB10-VL User Manual Set the on-duty time and press [M/OK]. Set the off-duty time and press [M/OK]. When Data download succeeds, Press [M/OK] to take out the USB disk or SD card. The SSRTemplateS.xls gets stored in the USB disk or SD card. The Schedule Information, Statistical Report of Attendance, Attendance Record Report, Exception Statistic Report, and Card Report can be viewed on a PC.
MB10-VL User Manual Schedule Information Report: The report allows you to view schedule records of all employees. Statistical Report of Attendance: The report allows you to query the attendance of each person in a specified period. Salaries can be calculated directly based on this report. Note: The unit of Work hour and Overtime hour in the Statistical Report of Attendance is HH: MM. For example, 17:50 indicates that the on-duty time is 17 hours and 50 minutes.
MB10-VL User Manual Card Report: The report can substitute for clock-based cards and can be sent to each employee for confirmation. Download Att. Setting Report If shifts are complex or the shifts of a person are not fixed, it is recommended that the attendance setting report be downloaded and shifts and schedules be set for employees in the attendance setting report. Select Download Att. Setting Report and press [M/OK]. Open the setting "AttSettingE.xls" in the USB disk or SD card on a PC.
MB10-VL User Manual Enter the On-duty and Off-duty time in the corresponding columns, where the First time zone shall be the On-duty or Off-duty time of Time 1 of Shift Setting, and the Second time zone shall be the On-duty or Off-duty time of Time 2. For the correct schedule time format, see "What is the correct time format used in the setting reports" in the "Self-Service Attendance Terminal FAQs.
MB10-VL User Manual Select Upload Att. Setting Report on the Report interface and press [M/OK]. After uploading, remove the USB disk or SD card. At this time, the employee information, shift, and department in the setting report can be viewed respectively by the Management User, Shift Number, and Department available in the device. Or the above information and scheduling information can be seen in the standard download report.
MB10-VL User Manual 12 Access Control Select Access Control on the main menu interface. Access Control Options To set the parameters of the control lock of the terminal and related equipment. Select Access Control Options on the Access Control interface. P a g e | 66 Copyright©2021 ZKTECO CO., LTD. All rights reserved.
MB10-VL User Manual Item Description Door Lock Delay (s) The length of time that the device controls the electric lock to be unlocked. Valid value: 1~10 seconds (0 second represents disabling the function). Door Sensor Delay (s) If the door is not closed and locked after opening for a certain duration (Door Sensor Delay), an alarm will be triggered. The valid value of Door Sensor Delay ranges from 1 to 255 seconds.
MB10-VL User Manual 13 USB Manager Upload or download data between the device and the corresponding software using a USB disk. Before uploading/downloading data from/to the USB disk, insert the USB disk into the USB slot first. Select USB Manager on the main menu interface. USB Download Select Download on the USB Manager interface. Item Description Attendance Data Import all the attendance data from the device to a USB disk.
MB10-VL User Manual USB Upload Select Upload on the USB Manager interface. Item Description Screen Saver To upload all screen savers from USB disk into the device. You can choose [Upload selected picture] or [Upload all pictures]. The images display as screensaver on the device’s main interface after upload. Wallpaper To upload all wallpapers from USB disk into the device. You can choose [Upload selected picture] or [Upload all pictures]. The images display as wallpaper after upload.
MB10-VL User Manual 14 Attendance Search When the identity of a user is verified, the record is saved on the device. This function enables users to check their access records. Select Attendance Search on the main menu interface and input the User ID. The interface is shown below. 1) Enter the user ID to be searched and select OK. If you want to search for records of all users, select OK without entering any user ID. 2) Select the time range for the records you want to search.
MB10-VL User Manual 15 Autotest The auto test enables the system to automatically test whether the functions of various modules are working normally, including the LCD, voice, sensor, keyboard, and clock tests. Select Autotest option on the main menu interface. Item Description Test All To automatically test whether the LCD, audio, camera and RTC are working normally.
MB10-VL User Manual 16 System Information With the system information option, you can view the storage status, the version, and firmware information of the device. Select System Info on the main menu interface. Item Description Device Capacity Displays the current device's user storage, password, fingerprint and face storage, administrators, and attendance records.
MB10-VL User Manual 17 Connect to ZKBioAccess IVS Software Set the Communication Address Device side 1. Tap COMM. > Ethernet in the main menu to set the IP address and gateway of the device. (Note: The IP address should be able to communicate with the ZKBioAccess IVS server, preferably in the same network segment with the server address) 2. In the main menu, click COMM. > Cloud Server Setting to set the server address and server port. Server address: Set the IP address as of ZKBioAccess IVS server.
MB10-VL User Manual Add Device on the Software Add the device by searching. The process is as follows: 1. Click Attendance > Attendance Device > Device > Search, to open the Search interface in the software. 2. Click Search, and it will prompt [Searching……]. 3. After searching, the list and total number of access controllers will be displayed. 4. Click Add in operation column, a new window will pop-up. Select Attendance Area and Time zone from each dropdowns and click OK to add the device.
MB10-VL User Manual Add Personnel on the Software 1. Click Personnel > Person > New: 2. Fill in all the required fields and click OK to register a new user. 3. Click Attendance > Attendance Device > Device > Control > Synchronize Software Data to the Device to synchronize all the data to the device including the new users. For more details, please refer to the ZKBioAccess IVS User Manual. P a g e | 75 Copyright©2021 ZKTECO CO., LTD. All rights reserved.
MB10-VL User Manual Appendix Self-Service Attendance Terminal FAQs 1. Does self-service attendance terminal support scheduling based on every other day? A: No. 2. Can the setting records downloaded from the device be edited on WPS software? A: Yes. Setting records are supported in Microsoft Office 2003, Microsoft Office 2007, and WPS Office 2012 Personal. 3. What is the attendance calculation flow adopted by the self-service attendance terminal? A: SSR attendance calculation flow.
MB10-VL User Manual 4. How to calculate special overtime hours? The following cases are deemed special overtime: a) When an EXCEL schedule record exists and attendance reports are used for attendance calculation, there are check-in and check-out records though there is no schedule (or rest is arranged) for the current date. b) When no EXCEL schedule record is available, there are check-in and check-out records though Saturday and Sunday are non-working days.
MB10-VL User Manual 6. What is the correct time format used in the setting reports? A. The correct time format is shown in the following table. Shift No. First Time Range On-duty Off-duty 1 09:00 18:00 2 09:00 12:00 3 9:5 18:00 Second Time Range On-duty Off-duty 13:30 18:00 Overtime Range Check-in Check-out B. Incorrect time formats are as follows: a) A time value is beyond the time range, such as 24:00.
MB10-VL User Manual B: The following uses four examples to describe the preceding principles. Example 1: Normal attendance Attendance Time Range 09:00 — 12:00 Attendance time of #1 employee Statistical result based on attendance rules 13:00 — 18:00 8:30, 8:35, 11:55,12:01, 12:50, 18:02,19:00 8:30 12:01 12:50 18:02 Description: The attendance time 8:30 and 8:35 are earlier than the on-duty time 9:00 and they are within the normal attendance time range.
MB10-VL User Manual Example 4: Absence Case 1: Attendance Time Range 09:00 — 12:00 Attendance time of #1 employee Statistical result based on attendance rules 13:00 — 18:00 8:50, 12:50, 18:01 8:50 12:50 18:01 Description: The attendance time 12:50 is adopted based on the principle of adopting a median in the attendance time range. For the attendance time range from 9:00 to 12:00, the normal check-out time range for the off-duty time 12:00 is from 12:00 to 12:30 (that is, 12:00 + (13:00 - 12:00)/2).
MB10-VL User Manual Statement on the Right to Privacy Dear Customers: Thank you for choosing this hybrid biometric recognition product, which was designed and manufactured by ZKTeco. As a world-renowned provider of core biometric recognition technologies, we are constantly developing and researching new products, and strive to follow the privacy laws of each country in which our products are sold. We Declare That: 1.
MB10-VL User Manual Eco-friendly Operation The product's "eco-friendly operational period" refers to the time during which this product will not discharge any toxic or hazardous substances when used in accordance with the prerequisites in this manual. The eco-friendly operational period specified for this product does not include batteries or other components that are easily worn down and must be periodically replaced. The battery's eco-friendly operational period is 5 years.
This equipment complies with RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator and your body ZKTeco Industrial Park, No. 32, Industrial Road, Tangxia Town, Dongguan, China. Phone : +86 769 - 82109991 Fax : +86 755 - 89602394 www.zkteco.com Copyright © 2021 ZKTECO CO., LTD. All Rights Reserved.