Installation & Quick Start Guide Smart Series Access Control Terminal Version: V2.
About This Manual All design and specification declared are subject to change without notice in advance. Not all products have the functions with , the real product shall prevail.
Contents 1. Safety Precautions ................................................................................................................................................................ 1 2. Packing List ............................................................................................................................................................................... 3 3. Overview of Operation Panel .............................................................................................
6.4 User Management .............................................................................................................................................. 22 6.5 Verification................................................................................................................................................................ 26 6.6 Data Management ..............................................................................................................................................
1. Safety Precautions Thank you for using our products. Please read this manual carefully before using this product for a comprehensive understanding so as to avoid causing unnecessary damages to the product. Important Notes 1. Do not place the device under strong light. 2. Use regulated 12V DC power source (separately purchased and recommend using Uninterrupted Power Supply with backup battery option considering of power failure). 3.
4. Mount the device at a comfortable height, typically between 1.4~1.5 meter from the ground. 5. After installation, remove protective film from the device display and fingerprint sensor. 6. To prevent being accidentally locked out while testing the exit button, keep a person on the inside of the door. 7. Run the auto-test function to confirm that installation is successful. 8.
2. Packing List 1 Access Device 1 Star Screw 1 Screw Driver 1 CD 4 Diodes (FR107) 4 Wall Plugs /Screws 2.
3.
Back 3.
4.
The diagram of system construction U Disk PC TCP/IP Lock Door Door Sensor Wiegand Card RS485 Card Exit Button Alarm Doorbell 4.
5. Installation 5.1 Installation of Device 1. Remove the bottom screw. 8 Installation & Quick Start Guide 2. Take out the Back Cover. 3. Fix the Back Cover on the wall with screwdriver.
4. Fix the device on the Back Cover. 5. Tighten the bottom screw. 5.
5.2 Connect with peripheral equipment Caution: Please make sure the power is cut off before wiring; otherwise it is possible to damage the device. 1). Door Sensor Connection 2). Button Connection 3). Alarm Connection 4). Doorbell Connection 5).
Selecting door lock: The choice of lock depends firstly on the door-electric strikes or bolts, magnetic locks, turnstiles or barriers are all options depending firstly on the architecture-and secondly on the required resistance to attach. Please consult your supplier for more info. Connect with electric lock: After the user verified the identity, the device will output the unlock signal. The device supports NO (Normally Open) LOCK and NC (Normally Close) LOCK.
NC Lock FR107 NO Lock FR107 The device and lock are powered by one adapter. The device and lock are powered by one adapter. DC 12V However, in the following three scenarios, it is recommended that the door lock has an independent power source, and is NOT powered by the device. Show as Figure 3, 4. 1. If the door lock voltage is not 12V DC, then provides separate power to the door lock.
2. If the door lock runs on 12V DC, but requires more than 1A (amp), then provide separate power to the door lock. 3. If the distance between the device and door lock is greater than 15 feet, then provide separate power to the door lock. Lock Power NC Lock FR107 FR107 NO Lock Lock Power The device and lock are powered by independent adapter. DC 12V The device and lock are powered by independent adapter. DC 12V 5.
6). RS485 Connection RS485 serial port will not be used as the communication port between the device and PC, which only connect external 485 reader (such as FR1200/ FR1300). Connection of 485 reader is shown as Figure 5.
7). Wiegand Function Wiegand Output: This device provides standard Wiegand 26 output, which can be used as reader. The distance from the controller to device cannot be more than 15 meter (If the signal must be transferred much further or there is a strong interference around, please adopt a Wiegand signal amplifier). Wiegand Input: The device has Wiegand input function, can connect the external card reader.
Wiegand Card Reader Access Controller 8).
5.3 Test and examine after installation Make a test and examine prior to power on, inspect whether the lock driver is OK or not. 1. The green LED begins to glitter after power up. 2. Enter [Main menu] > [Autotest] > [Test All]. 3. Enter [Main menu] > [User Mgt.] > [New User] > [Fingerprint], enroll a fingerprint, and use the fingerprint to test access system and door lock. 4. If there is no any problem, please delete this enrolled fingerprint. 5.
with, it will send an alarm signal. If the administrator was lost, you can wait about 30 seconds (there is a short beep tip) after the device is disassembled from the wall, then press the tamper switch three times to access the device menu.
6. Quick Start Guide Press to enter main menu, include User Management (User Mgt.), User Role Setting (User Role), Communication Setting (COMM.), System Setting (System), Personalize Setting (Personalize), Data Management (Data Mgt.), Access Control Setting (Access Control), USB Management (USB Manager),Attendance Search, Print Setting (Print), Autotest and System Information (System Info). 6.1 Communication Setting Press [COMM.] icon in main menu to enter the communication setting (COMM.) Interface.
and external reader, whether to enable the print function, and baud rate for the communication between the device and printer. PC Connection: Set Device ID and password for the connection between the device and software. The default password is 0 (that is, no password). Wiegand: To configure Wiegand Function. 6.2 System Setting Press [System] icon in main menu to enter the system setting (System) Interface Date/Time: To set device’s Date and Time, and Daylight Saving Time as required.
Match Threshold, 1:N Match Threshold, FP Sensor Sensitivity, 1:1 Retry Times and Fingerprint Image. Reset: To restore all system parameters to factory default settings (Note: All users’ information and verification records saved in the device will not be deleted after reset). USB Upgrade: To upgrade the firmware with the upgrade file saved in the U disk (It is not recommend to upgrade firmware in general case). 6.
Combined Verification: To set access control combinations. A combination consists of a maximum of 5 access control groups. Anti-Passback Setup: To prevent passing back which causes risks to security. Once it is enabled, entry and exit records must be matched in order to open door. In Anti-Passback, Out Anti- Passback and In / Out Anti-Passback functions are available. Duress Options: Set the duress alarm ways and alarm delay time as required. 6.4 User Management Press [User Mgt.
Enroll Fingerprint 1. Press[Fingerprint] in New User,the Enroll Fingerprint interface is displayed. 2. According to the operation prompt information, place finger on the Fingerprint Sensor properly three times until enrollment succeeds, and then return to the New User interface automatically. 3. Press to return and save user information. Enroll Badge Number 1. Press [Badge Number]in New User,the Enroll Badge Number interface is displayed. 2.
Search User 1. Press [All Users] icon in Use Mgt. to enter All Users interface, shown as left figure. 2. Input user ID or name in the search box. (Note: You can input user name with the intelligent input.) 3. Press [OK] to locate the specified user. Edit User After search the specified user, click the user to enter left interface. Press [Edit] to enter the Edit interface. Detail operations of editing are the same as adding user (The user ID cannot be edited).
Delete User 1. After search the specified user, click the user and press [Delete] to enter left interface. 2.Select delete type (Delete User, Delete Fingerprint Only, Delete Password Only, Delete Badge Number Only), and then press [OK] to confirm and carry out the corresponding delete operation. Note: (1) Based on the information registered by a user, the device displays the optional operation types.
User Access 1. In [New User] or [Edit] interface, press [Access Control Role] to enter the Access Control setting interface, shown as left figure. 2. Set the Access Group, Verification Mode, Time Period and select Duress Fingerprint as required. 6.
figure 1 figure 2 Verification by Password 1. In initial interface, press to enter the user ID Input interface, shown as figure 3. 2. Input user ID which needs to do password verification and press [OK], figure 4 will display. 3. Press icon to enter password input interface, shown as figure 5. 4. Input the correct password (same as inputting ID Number) and press [OK] to confirm the password. After verification succeed, figure6 will display. 6.
figure 3 figure 4 figure 5 figure 6 6.6 Data Management Press [Data Mgt.] icon in main menu to enter the Data Management (Data Mgt.) interface. Delete Data: Delete data saved in the device, such as attendance data, all data, admin role, access control, wallpaper, screen savers and backup data. Backup Data: Backup the business data or system data to device or USB disk.
Restore Data: Restore the backup data saved in device or USB disk to device. 6.7 USB Manager Press [USB Manager] icon in main menu to enter the USB Manager interface. Download: Download all attendance logs or user information to the USB Disk. And then import logs into the Access 3.5 software through Import Data From USB disk function, and then view Access Report as required. Upload: Upload user information, screen saver or wallpaper (stored in USB Disk) into the device. 6.
Download Options: Set whether to enable the Delete ATT Data option. 6.8 View Access Report 1. Connect the device to the network. 2. Run Access3.5 software. 3. Add the device to the software, download logs from device (you can use the USB Disk to download logs too), and then analyze logs and view the access report as required. Bundled Access3.5 Security System is unique software. For detailed operations, refer to Access3.5 software user manual in the CD.
7. Others The following equipments are needed for an access control system but are not included in the standard package. Name PC Doorbell 485 Reader Picture Name Lock Exit Button Picture Name Picture Door Sensor Alarm Wiegand Card USB Disk Reader 7.
Ethernet Cable 32 Installation & Quick Start Guide Access Switch Control Panel
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. 34 Consult the dealer or an experienced radio/TV technician for help.