User's Manual

Uniwave Additional System Setup
User Manual
Copyright © 2022 Zinwave. All rights reserved. 11-14
units are missing. Apply a new system setup to acknowledge them”. This is because the system has
changed from the baseline configuration set up after the Apply button was pressed.
Do not make any equipment changes while the system is validating its set up as this will invalidate any
System Setup process and the setup will fail. A message will be displayed indicating the failure and
request that you run System Setup again.
11.3.1 Hub
If a Remote Unit or Secondary Hub is disconnected from the system by removing either its power supply
or optical link, and then it is subsequently reconnected, it will restore the same configuration. If a
different unit is installed in its place, the new unit will have factory default configuration (unless restored
from a previous configuration elsewhere) and must be changed through the Hub Setup page and by
re-running the System Setup process to set the correct matrix configuration.
11.3.2 Remote Unit
If a Remote Unit is disconnected from the system, when the same unit is reconnected to the same
optical module, the system recalibrates the links and applies the stored settings. If a different unit is
reconnected, the system sets the unit to its default condition. Edit the System Setup to input its desired
values.
11.3.3 Optical Module
If a link is broken either due to fault or intervention the system automatically recalibrates the link and
applies the appropriate gains when the system is restored even if a different unit is swapped into the
system.
11.4 Factory Reset of a Primary Hub
It may be necessary to set the Hub back to factory default values when redeploying or reconfiguring
equipment.
The reset button can be found behind the small hole located to the left of the Alarm Serial interface. If
an installation was interrupted or if there has been a catastrophic issue with a Hub that cannot be
recovered, you can return the Hub to factory settings. This requires a physical reset to the system.
To reset a Hub to factory settings:
1. Using a small device (such as an open paper clip), push the Reset button located on the
front of the Hub and hold in for 10 seconds.