User's Manual

Uniwave Initial System Setup
User Manual
Copyright © 2022 Zinwave. All rights reserved. 10-12
PA Health is highlighted amber when there is 8dB or greater difference between the Tx output power
and the expected level from measuring the input power and red if there is no measurable output
power. A fault may actually be due to mismatch at the Tx port of the RU, rather than the PA.
If the background RF pickup is > -30dBm when the DAS is off it shows amber; if it is > -20dBm it shows
red. The test for each RU includes an “off” measurement and 3 test frequencies, so for a test on each
transmitting RU there are many “off” measurements measured on all of the Rus. This is presented as
a range of values, giving an indication that the background pickup might be bursty.
If Tx-Rx isolation is in the range -45 to -40dB, it shows amber; if it is more coupling than that it shows
red; if the background RF pickup was strong enough to compromise the measurement, it also shows
as amber and the result has “>=” added to the result text. It means that the Tx-Rx isolation measurement
had a smaller received level than the Rx level when the DAS was off.
If cross-coupling is in the range -50 to -45dB it is shown as amber; stronger than -45dB is it red. Strong
coupling from one RU’s Tx to another RU’s Rx is not to be expected.
Sample RF System Check View showing two RUs amber highlighted Tx/Rx Antenna Isolation (dB)
values due to the “>=” prefix.