User's Manual

Uniwave Hub and Module LEDs
User Manual
Copyright © 2022 Zinwave. All rights reserved. 3-14
Left
Middle
Right
Status
Optical Module inserted in invalid slot. (E.g. In an input
(rear) slot).
Off
Off
Green
Optical Module successfully detected, starting discovery
of downstream system elements.
Off
Red
Green
Potential communication failure state: No incoming light
on fiber or no downstream system elements have
responded after several communication attempts
(discovery continues).
Off
Green
Green
Communication success state: communication with at
least one downstream system element successfully
established.
Green
Flash
Green
Green
Optical calibration and auto-setup of downstream units in
progress, and/or one or more downstream Remote Units
have their radio transceivers disabled.
Green
Green
Green
Optical Module and all downstream system elements
operating normally.
3.4.3 Transport Module
The following table shows a typical LED start up sequence for a fully enabled Transport Module plugged
into the front slot of a UniTransport Hub.
Left
Middle
Right
Status
Off
Off
Dull
Red
Initial power-up. Power present on Hub allowing
Transport Module to be detected; or
Transport Module NOT Enabled through System Setup.
Off
Off
Green
Transport Module successfully detected, starting
discovery of downstream Primary Hub.
Off
Red
Green
Potential communication failure state: No incoming light
on fiber or no downstream system elements have
responded after several communication attempts
(discovery continues).
Off
Green
Green
Communication success state: communication
established with a downstream Primary Hub.
Green
Flash
Green
Green
Optical calibration and auto-setup of downstream units in
progress, and/or RF path to downstream Primary Hub is
disabled.
Green
Green
Green
Transport Module is connected to active downstream
Primary Hub.
The following table shows a typical LED start up sequence for a fully enabled Transport Module plugged
into the rear slot of a Primary Hub.