Hanshow ESL Controller HS_C09959 Product Manual V1.0.2 HS-AP-GEN3001 For more information, visit our website at: http://www.hanshow.
Hanshow ESL Controller HS_C09959 Product Manual V1.0.2 STATEMENT This document and all its contents contained remain the proprietary material of Zhejiang Hanshow Technology Co., Ltd. (Hanshow) and are protected by Chinese laws and applicable international conventions on copyrights.
Hanshow ESL Controller HS_C09959 Product Manual V1.0.2 ABOUT THE MANUAL The manual mainly introduces the role of HS_C09959, functional, hardware parameters, features and precautions, as well as all the information that can help you install and achieve good performance. Thank you very much for using the HS_C09959 of Hanshow. Please read the product manual carefully before using this product, retain the document for subsequent use or for the next owner.
Hanshow ESL Controller HS_C09959 Product Manual V1.0.
Table of Contents Table of Contents STATEMENT ................................................................................................................................ I ABOUT THE MANUAL ................................................................................................................ II TARGET USERS ......................................................................................................................... II SYMBOL DESCRIPTION ............................................
Table of Contents 8 FCC ID warning ...................................................................................................................... 24 8.1 Warning for nameplate ................................................................................................ 24 8.2 Warning for product manual ........................................................................................ 24 V Hanshow Copyright Reserved © Zhejiang Hanshow Technology Co., Ltd.
List of Figures List of Figures Figure 1-1 Overall system architecture of ESL controller ...................................... 1 Figure 2-1 External interface of HS_C09959 ......................................................... 5 Figure 2-2 Front panel of HS_C09959 ................................................................... 6 Figure 2-3 Nameplate information for HS_C09959................................................ 7 Figure 3-1 HS_C09959 installation .........................................
List of Tables List of Tables Table 2-1 Basic configuration for HS_C09959....................................................... 3 Table 2-2 Function description for each interface .................................................. 5 Table 2-3 Status code meaning ............................................................................. 8 Table 2-4 HS_C09959 view parameter ................................................................. 8 Table 4-1 Configuration item description .......................
Hanshow ESL Controller HS_C09959 Product Manual V1.0.2 1 Overview HS_C09959 is the third generation wireless Access Point (AP) researched and developed independently by Hanshow Technology Co., Ltd, which is highly integrated to meet rapid development of new-generation AP. HS_C09959 achieves higher performance, smaller volume and low power, making customer to have a better data services experience. HS_C09959 works at the wireless frequency band of 2.4G.
Hanshow ESL Controller HS_C09959 Product Manual V1.0.2 Uplink: HS_C09959 will forward heartbeats data and other information to ESLWorking platform based on the ESL wireless protocol standard. 1.2 Features The main features of HS_C09959 are as follows: Operation System (OS): embedded Linux operation system, it works for data interaction with ESL-working system, including the registration of ESL controller system, heartbeat reception, data transmission, and support for on-line upgrade, etc.
Hanshow ESL Controller HS_C09959 Product Manual V1.0.2 2 Hardware feature This chapter presents the information, including the basic configuration, physical interface, indicator meaning, nameplate information, status code information and view parameter. 2.1 Basic configuration HS_C09959 has the following basic configuration, as shown in Table 2-1. Table 2-1 Basic configuration for HS_C09959 HS_C09959 specifications Power supply module Input voltage DC 12V or POE 802.
Hanshow ESL Controller HS_C09959 Product Manual V1.0.2 HS_C09959 specifications Automatic flip Support DHCP Support POE module Input voltage 36 ~ 57V DC Output voltage 12V Rated current 1A Maximum power 12W Standard IEEE 802.3af/at Power parameter Idle state power 12V, 160mA Maximum power 12V, 370mA Temperature 4 Operating temperature 0℃ ~ 50℃ Storage temperature -30℃ ~ 70℃ Hanshow Copyright Reserved © Zhejiang Hanshow Technology Co., Ltd.
Hanshow ESL Controller HS_C09959 Product Manual V1.0.2 2.2 Physical interface HS_C09959’s physical interfaces are as shown in Figure 2-1, and each interface’s function is illustrated in Table 2-2. Figure 2-1 External interface of HS_C09959 Table 2-2 Function description for each interface No. Interface name Description Press and hold: restore factory settings, press this button for more than 5 seconds, Press: HS_C09959 could switch between enabling DHCP and fixed IP (192.168.1.
Hanshow ESL Controller HS_C09959 Product Manual V1.0.2 No. 8 9 Interface name Description Light LED indicator is used for power status. For more information, refer to section of 2.3 Two-digit nixie tube Green, which is HS_C09959 ID got from ESL-Working when HS_C09959 is connected to ESL-Working successfully. (The direction of Nixie light is aligned to Hanshow logo direction on the panel.) 2.
Hanshow ESL Controller HS_C09959 Product Manual V1.0.2 No.
Hanshow ESL Controller HS_C09959 Product Manual V1.0.2 2.5 Status code meaning The definition of two-digit Nixie light displayed on panel is shown as Table 2-3. Table 2-3 Status code meaning Code value Description -- AP is not connected to ESL-Working Number AP has been connected to ESL-Working, and the number currently displayed is ID, the range of 1 ~ 99 (If the ID is over 99, just display the last two-digit).
Hanshow ESL Controller HS_C09959 Product Manual V1.0.2 3 Product installation 3.1 Installation requirements In actual use, HS_C09959 should be installed in a higher position to achieve better transmission and coverage. Moreover, the higher the installation height, the smaller the device spacing should be, as shown in Figure 3-1.
Hanshow ESL Controller HS_C09959 Product Manual V1.0.2 3.2 Installation accessories HS_C09959’s standard installation accessories and assembly drawing is shown in Figure 3-2 and Figure 3-3. Figure 3-2 Standard installation accessories for HS_C09959 Figure 3-3 Assembly drawing for HS_C09959 Note: How to install HS_C09959, Ceiling Horizontal Suspended Mounting is recommended. For more detailed information, refer to (HS-AP-GEN3002) Hanshow ESL controller HS_C09959 Installation Manual.
Hanshow ESL Controller HS_C09959 Product Manual V1.0.2 4 Product operation 4.1 Key operation Reset key supports press and hold and press that owns different function respectively. 4.1.1 Press Press is used to switch IP address acquisition mode. This feature is strictly limited and just to operate when AP is not connected to the network. AP address will switch between DHCP and static IP with each press. When AP works at DHCP client mode, its IP address will get from DHCP server.
Hanshow ESL Controller HS_C09959 Product Manual V1.0.2 4.2 Parameter setting HS_C09959 supports Web configuration mode, that is, user can manage the AP via Web. 4.2.1 Homepage You can logon the HSC09959 IP address to configure the page. For example: If HS_C09959 IP is 192.168.51.100, logging on to http://192.168.51.100, that is, enter the following page to configure related parameters, as shown in Figure 4-1 and Figure 4-2.
Hanshow ESL Controller HS_C09959 Product Manual V1.0.2 Figure 4-2 Configuration homepage HS_C09959’s configuration page is as shown in Table 4-1. Table 4-1 Configuration item description Configuration item Description Network Used to set the network parameters of HS_C09959, such as DHCP switch, IP address, subnet mask, etc.
Hanshow ESL Controller HS_C09959 Product Manual V1.0.2 4.2.2 Network setting Network setting is used for setting the network parameter of HS_C09959. IP address acquiring mode includes DHCP or static IP, as show in Figure 4-3. Figure 4-3 Network configuration page The detailed configuration item is illustrated as shown in Table 4-2.
Hanshow ESL Controller HS_C09959 Product Manual V1.0.2 Configuration item Description Enable DHCP, to get DNS from DHCP. MAC Unique MAC address of device, refer to nameplate Note: Network modified will effective immediately, and you need to re-enter setting website to access. 4.2.3 ESL-Working setting ESL-Working setting can set IP address and port number of ESL-Working, as shown in Figure 4-4.
Hanshow ESL Controller HS_C09959 Product Manual V1.0.2 Configuration item Description Port number of ESL-Working: Port number When AUTO search is set to ON, this port number is the target one for AP accessible to ESL-Working; When AUTO search is set to OFF, this port number is the target one for AP accessible to ESL-Working. SSL Whether to use SSL to connect securely with ESL-Working Note: After the domain name address of ESL-Working is set, you need to check if DNS server is configured correctly.
Hanshow ESL Controller HS_C09959 Product Manual V1.0.2 Figure 4-5 Reboot device 17 Hanshow Copyright Reserved © Zhejiang Hanshow Technology Co., Ltd.
Hanshow ESL Controller HS_C09959 Product Manual V1.0.2 4.2.5 AP description The description setting item of HS_C09959 can add custom device information description for record and recognition, as shown in Figure 4-6. Figure 4-6 AP description 18 Hanshow Copyright Reserved © Zhejiang Hanshow Technology Co., Ltd.
Hanshow ESL Controller HS_C09959 Product Manual V1.0.2 4.2.6 Change admin password Change admin password is used for changing the password of configuration page, as shown in Figure 4-7. Figure 4-7 Change password 4.2.7 Restore factory settings It can restore the factory setting of AP. You need to check again on the pop-up dialog, click OK. The AP will restore factory setting and restart, as shown in Figure 4-8. Please wait for about 1min to restore factory setting.
Hanshow ESL Controller HS_C09959 Product Manual V1.0.2 Figure 4-8 Restore factory settings Note: The effect is the same as the press button. Don’t cut off the power during the process of restoring factory setting, otherwise the device will be damaged. 4.2.8 Upgrade firmware Upgrade firmware: Used for on-line upgrading of main system and RF subsystem. Notice: Don’t cut off the power during upgrading process, otherwise the system will be damaged. Upgrade the main PCB and four-way sub-PCB of RF.
Hanshow ESL Controller HS_C09959 Product Manual V1.0.2 5 Workflow 1. Before starting HS_C09959, please check if the power cord and network cable are connected correctly in first. 2. Whether to use the standard 12V adapter or POE mode power supply 3. After powered-on, the power indicator on the HS_C09959 panel is on and the system starts to boot. 4. The startup time is about 1min. After the system is started, both of system status light and network status light is on, all of which indicate working status.
Hanshow ESL Controller HS_C09959 Product Manual V1.0.2 6 Package 6.1 Package drawing HS_C09959’s physical packaging is shown as Figure 6-1. Figure 6-1 Package of HS_C09959 6.2 Package contents HS_C09959’s package contains: HS_C09959 device (with the product model on the nameplate) Sheet metal mounting bracket Screws Metal cable tie Quick Start Guide 22 Hanshow Copyright Reserved © Zhejiang Hanshow Technology Co., Ltd.
Hanshow ESL Controller HS_C09959 Product Manual V1.0.2 7 Precautions When installing and using HS_C09959 (hereinafter referred to as AP), please pay attention to the following precautions and suggestions: Table 7-1 Precautions and suggestions Item Description Pre-installation check Before connecting the cables, please use the testing tool to check if the network cable is normal, and ensure AP can work normally.
Hanshow ESL Controller HS_C09959 Product Manual V1.0.2 8 FCC ID warning 8.1 Warning for nameplate This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. 8.