GENERAL DATA
Life Expectancy Minimum operations
Mechanical 5 x 10
6
Electrical 1 x 10
5
at 10 A 120 VAC Res.
Operate Time (max.) 10 ms at nominal coil voltage, standard
15 ms at nominal coil voltage, sensitive
Release Time (max.) 5 ms at nominal coil voltage
(with no coil suppression)
Dielectric Strength 1000 Vrms contact to contact
(at sea level for 1 min.) 4000 Vrms contact to coil
Insulation Resistance 1 x 10
9
ohms minimum at 500 VDC
Dropout Greater than 10% of nominal coil voltage
Ambient Temperature At nominal coil voltage
Operating -40°C (-40°F) to 85°C (185°F)
Storage -40°C (-40°F) to 105°C (221°F)
Vibration 0.062" DA at 10–55 Hz
Shock
Operating 10 g for 11 ms 1/2 sine pulse
(no contact opening >100 usec)
Mechanical 100 g for 11 ms 1/2 sine pulse
Enclosure P.B.T. polyester
Terminals Tinned copper alloy, P.C.
Max. Solder Temp. 270°C (518°F)
Max. Solder Time 5 seconds
Max. Solvent Temp. 80°C (176°F)
Max. Immersion Time 30 seconds
Weight 7 grams
COIL
Power
At Pickup Voltage 196 mW (Standard Coil)
(typical) 113 mW (Sensitive Coil)
Max. Continuous 676 mW at 20°C (68°F)
Dissipation
Temperature Rise 42°C (76°F) (Standard Coil)
24°C (44°F) (Sensitive Coil)
Temperature
Max. 155°C (311°F)
CONTACTS
Arrangement SPST N.O. (1 Form A)
SPDT (1 Form C)
Ratings Resistive load:
Max. switched power: 150 W or 1400 VA N.O.
90 W or 850 VA N.C.
Max. switched current:10 A N.O., 3 A N.C..
Max. switched voltage: 30 VDC or 277 VAC
UL, CUR 10 A at 125 VAC, Res., 100k cycles, 85°C
5 A at 277 VAC, Res., 100k cycles, 85°C
5 A at 30 VDC, Res., 100k cycles, 85°C
1
/10 HP at 125 VAC, 100k cycles, 85°C
1
/10 HP at 250 VAC, 100k cycles, 85°C
3 A at 277 VAC Res., 100k cycles, 85°C
3 A at 30 VDC Res., 100k cycles, 85°C
Material Silver tin oxide
Resistance < 0.1 Ohm
(24 V, 1 A voltage drop method)
AZ9405
1/8/15
10 AMP MINIATURE
POWER RELAY
FEATURES
10 Amp switching capability
SPST-N.O. and SPDT configurations
4 kV dielectric strength
Epoxy sealed version available
Class F insulation system standard
UL, CUR file E44211
NOTES
1. All values at 20°C (68°F).
2. Relay may pull in with less than “Must Operate” value.
3. Specifications subject to change without notice.
(N.O.)
(N.C.)
TUV R50290833

Summary of content (2 pages)